Moxa Technologies EDS-308, EDS-305 manual DIP Switch Settings, LED Indicators

Page 13

DIP Switch Settings

EDS-308 Series DIP Switches

EDS-305 Series DIP Switches

ONDIP

1 2 3 4 5 6 7 8

 

ON

 

DIP

1

2

3

4

5

ON: Enables the corresponding PORT Alarm. If the port’s link fails, the relay will form an open circuit and the fault LED will light up.

Off: Disables the corresponding PORT Alarm. The relay will form a closed circuit and the Fault LED will never light up.

LED Indicators

The front panel of MOXA EtherDevice Switch contains several LED indicators. The function of each LED is described in the table below.

LED

Color

State

Description

P1

AMBER

On

Power is being supplied to power input P1

Off

Power is not being supplied to power input P1

 

 

 

 

 

 

P2

AMBER

On

Power is being supplied to power input P2

 

 

Off

Power is not being supplied to power input P2

 

 

 

 

 

 

 

 

On

When the corresponding PORT alarm is

 

 

enabled, and the port’s link is inactive.

 

RED

 

Fault

 

 

Off

When the corresponding PORT alarm is

 

 

 

 

enabled and the port’s link is active, or when the

 

 

 

corresponding PORT alarm is disabled.

 

 

 

 

 

 

On

TP port’s 10 Mbps link is active

10M

GREEN

 

 

Blinking

Data is being transmitted at 10 Mbps

 

 

 

 

 

 

Off

TP Port’s 10 Mbps link is inactive

 

 

 

 

 

 

On

TP port’s 100 Mbps link is active

100M (TP)

GREEN

 

 

Blinking

Data is being transmitted at 100 Mbps

 

 

 

 

 

 

Off

100BaseTX Port’s link is inactive

 

 

 

 

 

 

On

FX port’s 100 Mbps is active

100M (FX)

GREEN

 

 

Blinking

Data is being transmitted at 100 Mbps

 

 

 

 

 

 

Off

100BaseFX port is inactive

 

 

 

 

12

Image 13
Contents EDS-308/305 Hardware Installation Guide Features Package ChecklistOverview Rear Panel View Panel Layout of EDS-305 SeriesPanel Layout of EDS-308 Series Mounting Dimensions unit = mm Step DIN-Rail MountingStep Wall Mounting OptionalSafety First Wiring RequirementsWiring the Alarm Contact Grounding Moxa EtherDevice Switch Top View Front View Wiring the Redundant Power Inputs10/100BaseTX Ethernet Port Connection Communication ConnectionsAlarm Contact Redundant Power InputsLED Indicators DIP Switch SettingsSwitching, Filtering, and Forwarding Dual Speed Functionality and SwitchingSwitching and Address Learning Auto MDI/MDI-X ConnectionAuto-Negotiation and Speed Sensing SpecificationsWarranty Revision History Moxa Internet Services