Wiring Requirements

ATTENTION

Safety First!

Be sure to disconnect the power cord before installing and/or wiring your EDS-208.

Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.

If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.

You should also pay attention to the following items:

yUse separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.

yNOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.

yYou can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.

yKeep input wiring and output wiring separated.

yIt is strongly advised that you label wiring to all devices in the system when necessary.

Grounding EDS-208

Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the right most contact of the 3-contact terminal block to the grounding surface prior to connecting devices.

ATTENTION

This product is intended to be mounted to a well-grounded mounting surface such as a metal panel.

- 6 -

Image 6
Contents Moxa EtherDevice Switch Package Checklist FeaturesOverview Panel Layout of EDS-208 Rear ViewPanel Layout of EDS-208-M-SC/ST Mounting Dimensions unit = mm DIN-Rail MountingWiring Requirements Safety FirstGrounding EDS-208 Wiring the Power Inputs Communication Connections100BaseFX Ethernet Port Connection LED Indicators Dual Speed Functionality and SwitchingAuto MDI/MDI-X Connection Specifications Switching, Filtering, and ForwardingSwitching and Address Learning Auto-Negotiation and Speed SensingMechanical PowerOptical Fiber EnvironmentTechnical Support Contact Information