Moxa Technologies EDS-205 manual Wiring Requirements, Safety First

Page 5

To remove Moxa EDS-205 from the DIN-Rail, insert a flat-blade screw driver horizontally into the DIN-Rail kit under the EDS-205, and then pull it upwards and release EDS towards you away from the DIN-Rail.

Wiring Requirements

Safety First!

Be sure to disconnect the power cord before installing and/or wiring your Moxa EtherDevice Switch.

Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.

If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.

Safety First!

Be sure to disconnect the power cord before installing and/or wiring your Moxa EtherDevice Switch.

Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.

If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.

You should also pay attention to the following points:

yUse separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.

yNOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.

yYou can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.

yKeep input wiring and output wiring separated.

yIt is strongly advised that you label wiring to all devices in the system when necessary.

Image 5
Contents EDS-205 Hardware Installation Guide Moxa EtherDevice SwitchPackage Checklist FeaturesEDS = Moxa EtherDevice Switch OverviewTop View Panel Layout of EDS-205 SerieseriesDIN-Rail Mounting Mounting DimensionsSafety First Wiring RequirementsWiring the Power Inputs Grounding Moxa EtherDevice Switch10/100BaseTX Ethernet Port Connection Communication ConnectionsDual Speed Functionality and Switching LED IndicatorsSwitching, Filtering, and Forwarding Auto MDI/MDI-X ConnectionAuto-Negotiation and Speed Sensing Switching and Address LearningSpecifications Technical Support Contact Information Regulatory Approvl