Moxa Technologies EDS-205 manual Grounding Moxa EtherDevice Switch, Wiring the Power Inputs

Page 6

Grounding Moxa EtherDevice Switch

Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the right most of 3-contact terminal block to the grounding surface prior to connecting devices.

This product is intended to be mounted to a well-grounded mounting surface such as a metal panel.

Wiring the Power Inputs

The two left-most contacts of the 3-contact terminal block connector on EDS’s top panel are used for EDS’s DC or AC inputs. Top and front views of one of the terminal block connectors are shown here.

STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals.

STEP 2: To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector.

STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on EDS’s top panel.

yOnly connect to a class 2 power supply.

yUse 60/75°C copper (CU) wire 28-12 AWG only.

yUse a maximum torque of 4.5 in-lb.

Image 6
Contents Moxa EtherDevice Switch EDS-205 Hardware Installation GuideEDS = Moxa EtherDevice Switch FeaturesPackage Checklist OverviewPanel Layout of EDS-205 Serieseries Top ViewMounting Dimensions DIN-Rail MountingWiring Requirements Safety FirstGrounding Moxa EtherDevice Switch Wiring the Power InputsCommunication Connections 10/100BaseTX Ethernet Port ConnectionSwitching, Filtering, and Forwarding LED IndicatorsDual Speed Functionality and Switching Auto MDI/MDI-X ConnectionSwitching and Address Learning SpecificationsAuto-Negotiation and Speed Sensing Regulatory Approvl Technical Support Contact Information