PA601 COMMERCIAL AMPLIFIER
REAR PANEL DESCRIPTION
OWNER'S MANUAL
FUSE
0.8A/250V FOR 230V~240V 1.5A/250V FOR 120V
F7,&'
7jbWiIekdZ7 fb_\_[h
Speaker Output 60W |
| Line In |
|
|
| |||
|
|
|
|
| ||||
|
|
|
|
|
| Balanced | ||
COM | 4 | 70V | 100V |
|
| Line Input | ||
|
|
|
|
| ||||
|
|
|
| Unbalanced |
|
|
| |
|
|
|
| On |
|
|
|
|
|
|
|
| Off | Line Out |
|
|
|
CLASS 2 WIRING | Loudness | G | – | + | ||||
|
|
|
|
| ||||
| £Èä£Ê>VÊV>ÞÊ Û`°]ÊÃ]Ê/8ÊÇx££Ê |
|
|
|
|
| ||
|
|
|
|
|
|
11 | 10 | 9 | 8 | 7 | 6 |
6.Balanced Input
Balanced line level signals connect to the (+),
7.Line In
The Line In connector is useful for receiving a
8.Line Out
Line Out connector is useful for providing unbalanced line level signal to another amplifier or other external device.
9.Loudness Contour EQ
This switch, when in the ON position, provides +4dB of boost at 100Hz and 8kHz. Use of this EQ is suggested to enhance music playback at low levels.
10.Output Terminal Strip
For loudspeaker connections, connect as follows or proceed to the setup section for typical wiring schemes.
COM - Speaker common or negative connection 4Ω - Connect to direct coupled loudspeakers
70V - Connect to transformer coupled, 70.7V loudspeakers with a total load impedance of 83Ω 100V - Connect to transformer coupled, 100V loudspeakers with a total load impedance of 167Ω
11.IEC AC Receptacle
Prior to connecting a grounded power cord the proper selection of the AC Line switch and fuse must be made. For 120VAC use the 1.6A/250V fuse and for 230~240VAC use the 1A250V fuse.