Moxa Technologies CP-114 Series Connecting the Fan-out Cable, Valid if JP5/6 is Left and S1 is on

Page 12

!S2 Data Mode Selection Switch for Port 1/2/3/4:

(Valid if JP5/6 is Left and S1 is ON)

ON* Set the RS-485 port to Automatic Data Direction Control Mode.

OFF Set the RS-485 port to By RTS Mode.

!JP1/2/3/4 Termination Resistor Port 1/2/3/4:

(Valid if JP5/6 is Left and S1 is ON)

Open * Not using Termination Resistor Short Using Termination Resistor

Installing the Industio CP-114 Series Board

The BIOS automatically assigns the IRQ number and I/O addresses for the Industio CP-114 Series board. Hence, it is a must to have the board plugged first before installing the software driver. After this, simply install the control board into the PC and then connect the connection cable.

Step 1: Power off the PC.

Warning ! Make sure your system is switched off before you start installing any board. If you don’t, you may risk damaging your system and the board.

Step 2: Remove the slot cover bracket if present.

Step 3: Plug the Industio CP-114 Series control board firmly into a free 32-bit PCI slot.

Step 4: Fasten the holding screw to fix the control board in place.

Connecting the Fan-out Cable

Step 5: Connect the fan-out cable (DB37 to DB9 x 4).

RS-422 RS-232 RS-485

JP5

RS-422 RS-232 RS-485

JP6

JP1

JP2

JP4

JP3

SW2

AUTO

 

O

 

 

 

N

 

 

1

2

3

4

By RTS

SW1 RS-485

O

 

 

 

N

 

 

 

1

2

3

4

RS-422

Fan-out Cable Industio CP-114

Step 6: Power on the PC and the BIOS will automatically set the IRQ and I/O address.

Note ! Each board must occupy one unique IRQ and four 8-byte I/O addresses, which are assigned automatically by the BIOS. However, you can select a free IRQ number manually via the PC’s BIOS setup for the PCI slot, but normally this method is not available for the I/O address. The possible IRQ numbers are 2, 3, 4, 5, 7, 10, 11, 12, and 15. The possible I/O addresses are from 0x0000 to 0xFFFF.

Step 7: Proceed with the software installation detailed in the next chapter, “Software Installation”.

2-2Industio CP-114 User's Manual

Image 12
Contents Fourth Edition, November Moxa Technical SupportIndustio CP-114 Series User’s Manual Copyright NoticeTrademarks DisclaimerMoxa Internet Services Following services are providedAbout This Manual Table of Contents Page Introduction OverviewFeatures Operating System SupportMoxa Serial Comm Tools Surge/Isolation Protection Installation Guide Check List Introduction Page Hardware Installation First Thing to Do Interface SettingsConnecting the Fan-out Cable Valid if JP5/6 is Left and S1 is onSoftware Installation Installing DriverWindows NT Page Software Installation Port NumberRx Fifo Trigger Tx Fifo Size Configuring Board and Port Windows 95/98 Removing DriverFirst Time Driver Installation Stage Page Windows Port Configuration Stage Port Number Board and Port Ready Stage Configuring Board and Port Updating Driver Removing Driver DOS Driver Setup Page TxD buf size RxD buf size F5 Group edit Loading Driver PComm Installation Serial Programming ToolsPComm Programming Library Diagnostic for Moxa boards only UtilitiesPage Terminal Emulator Installing API-232 Serial Programming ToolsData Scope DiagnoseHow to transmit and receive data for Windows NT, 95/98 & DOS RS-485 ProgrammingSolution Connection Cable and Cable Wiring RS-232 Cable WiringDTE Device Connection Cable and Cable Wiring DCE DeviceRS-422 Cable Wiring RS-422 Point-to-point RS-422 BroadcastingRS-485 Cable Wiring Impedance Matching and Termination Resistors DB37 Connector For RS-232 ModeFor RS-422 Mode For RS-485 ModePage Troubleshooting General TroubleshootingHardware causes and solutions Software Causes and SolutionsWindows NT system panic blue screen Specification Technical ReferenceUart 16C550C Page Industio CP-114 Series Customer name Company TelFax EmailDateReturn Procedure Revision History