!S2 Data Mode Selection Switch for Port 1/2/3/4:
(Valid if JP5/6 is Left and S1 is ON)
ON* Set the
OFF Set the
!JP1/2/3/4 Termination Resistor Port 1/2/3/4:
(Valid if JP5/6 is Left and S1 is ON)
Open * Not using Termination Resistor Short Using Termination Resistor
Installing the Industio CP-114 Series Board
The BIOS automatically assigns the IRQ number and I/O addresses for the Industio
Step 1: Power off the PC.
Warning ! Make sure your system is switched off before you start installing any board. If you don’t, you may risk damaging your system and the board.
Step 2: Remove the slot cover bracket if present.
Step 3: Plug the Industio
Step 4: Fasten the holding screw to fix the control board in place.
Connecting the Fan-out Cable
Step 5: Connect the fan-out cable (DB37 to DB9 x 4).
JP5
JP6
JP1
JP2
JP4
JP3
SW2
AUTO
| O |
|
|
| N |
|
|
1 | 2 | 3 | 4 |
By RTS
SW1
O |
|
|
|
N |
|
|
|
1 | 2 | 3 | 4 |
Fan-out Cable Industio CP-114
Step 6: Power on the PC and the BIOS will automatically set the IRQ and I/O address.
Note ! Each board must occupy one unique IRQ and four
Step 7: Proceed with the software installation detailed in the next chapter, “Software Installation”.