Moxa Technologies CP-114 Series user manual RS-485 Cable Wiring

Page 45

Connection Cable and Cable Wiring

RS-485 Cable Wiring

The RS-485 standard is an enhanced version of the RS-422 balanced line standard. It allows multiple drivers and receivers in a multidrop systems. As many as 32 drivers and 32 receivers can be put on any multidrop system.

The Industio CP-114 Series supports only 2-wire half-duplex RS-485 communication. Data+/- pins are served for both data transmitting and receiving, depending on the RTS signal.

RS-485 pin outs for the Industio CP-114 Series:

CP-114

1Data-(A)

2Data+(B)

5 GND

1Data-(A)

2 Data+(B)

5 GND

 

Multidrop RS-485 Half-duplex

CP-114

RS-485 Device 1

Master

Slave

2

Data+

Data+

1

Data-

Data-

5

GND

GND

RS-485 Device N

Slave

Data+

Data-

GND

See the section RS-485 Programming” of the chapter “Serial Programming Tools” for more RS-485 programming details.

Industio CP-114 User's Manual 5-5

Image 45
Contents Moxa Technical Support Fourth Edition, NovemberCopyright Notice Industio CP-114 Series User’s ManualTrademarks DisclaimerFollowing services are provided Moxa Internet ServicesAbout This Manual Table of Contents Page Overview IntroductionOperating System Support FeaturesMoxa Serial Comm Tools Surge/Isolation ProtectionInstallation Guide Check ListIntroduction Page First Thing to Do Interface Settings Hardware InstallationValid if JP5/6 is Left and S1 is on Connecting the Fan-out CableSoftware Installation Installing DriverWindows NT Page Software Installation Port NumberRx Fifo Trigger Tx Fifo Size Configuring Board and Port Removing Driver Windows 95/98First Time Driver Installation Stage Page Windows Port Configuration Stage Port Number Board and Port Ready Stage Configuring Board and Port Updating Driver Removing Driver DOS Driver Setup Page TxD buf size RxD buf size F5 Group edit Loading Driver PComm Installation Serial Programming ToolsPComm Programming Library Utilities Diagnostic for Moxa boards onlyPage Terminal Emulator Serial Programming Tools Installing API-232Diagnose Data ScopeRS-485 Programming How to transmit and receive data for Windows NT, 95/98 & DOSSolution RS-232 Cable Wiring Connection Cable and Cable Wiring DTE Device DCE Device Connection Cable and Cable WiringRS-422 Point-to-point RS-422 Broadcasting RS-422 Cable WiringRS-485 Cable Wiring Impedance Matching and Termination Resistors For RS-232 Mode DB37 ConnectorFor RS-422 Mode For RS-485 ModePage General Troubleshooting TroubleshootingHardware causes and solutions Software Causes and SolutionsWindows NT system panic blue screen Specification Technical ReferenceUart 16C550C Page Customer name Company TelFax EmailDate Industio CP-114 SeriesReturn Procedure Revision History