5.2. Connecting 32 or More Combination Cameras
Connect the Combination camera's control cable to the unit's Slave Connection Terminal, making sure to match their polarities.
Camera control terminal | Remote controller | |
GND |
Shielded
Termination switch: ON
| MASTER |
| SLAVE |
| ||
IN | OUT |
| A | B | C | D |
GND | GND | TERMINATION | GND | GND | GND | GND |
|
| OFF ON |
|
|
|
|
|
|
|
|
|
| Caution |
Up to 31
Combination camera
Ch 1 | Ch 2 | Ch 31 |
Termination switch | Termination switch | Termination switch |
OFF | OFF | ON |
Combination camera
Ch 32 | Ch 33 | Ch 62 |
Termination switch | Termination switch | Termination switch |
OFF | OFF | ON |
[Connection cables]
•Recommended cable type:
•If multiple cameras are connected to a single terminal, the total of each cable distance between connected equipment must be 1.2 km or less.
Interface unit
a
Combination |
| Combination |
camera |
| camera |
b
a + b + c < 1.2 km
c
Combination
camera
[Termination switch setting]
•Set the unit's termination switch to ON when the unit and the
•Make sure that the termination switches of the cameras connected to the system are set as follows.
Cameras other than the last connected camera: Termination switch OFF
Last connected camera: | Termination switch ON |
Interface unit
Combination
camera
Terminal switch
OFF
Combination
camera
Terminal switch
OFF
Combination
camera
Terminal switch
ON
6