Pelco manual Installation, Mounting AN EPS5000-300

Page 9

Installation

MOUNTING AN EPS5000-300

The power supply, which is 1 RU high, can provide redundant power to one or two fully populated RK5000PS-5U. To mount the power supply, follow these steps and refer to Figure 5.

1.Insert the EPS5000-300 into the rack.

2.Secure the EPS5000-300 to the rack with four of the supplied 10-32 x 0.750-inch screws and washers.

3.Connect each power supply to the RK5000PS-5U using the supplied over-molded cables. Figure 8 shows the EPS5000-300 providing redundant power to two RK5000PS-5U.

4.Plug in the AC power cords.

5.Turn on the power supply switches.

Figure 5. Mounting an EPS5000-300 into a Rack

If installing the EPS5000-300 into a square-hole rack, insert two cage nuts in each side of the square-hole rack as shown in Figure 6.

CAGE NUT

Figure 6. Inserting Cage Nuts

C1631M-B (9/06)

9

Image 9
Contents EPS5000-300 External Redundant Power Supply Page List of Illustrations ContentsC1631M-B 9/06 Radio and Television Interference Regulatory NoticesParts List Package ContentsBefore You Begin Shown Actual Size Description Front ViewBack View Mounting AN EPS5000-300 InstallationAttaching Rails Attaching Rails to AN EPS5000-300Connecting to an RK5000PS-5U Replacing a Power Supply ServiceElectrical SpecificationsC1631M-B 9/06 Product Warranty and Return Information ISO9001