APPLICATION EXAMPLES
Table A contains examples of products and the number of units that can be powered by each power supply, and is based on the VA rating of each product.
Table A. Product Capacity
|
| Power Supply Model |
| |
Product |
|
|
|
|
|
|
|
|
|
CDD Camera (12 VA maximum) | 4 | 8 | 16 | 16 |
|
|
|
|
|
DF5/DF5S with camera (3 VA) | 4 | 8 | 16 | 16 |
|
|
|
|
|
DF8A/PDF8 (12 VA maximum) | 4 | 8 | 16 | 16 |
|
|
|
|
|
Indoor Spectra (25 VA) | 1 | 4 | 8 | 16 |
|
|
|
|
|
Esprit (70 VA) | — | 1 | 3 | 6 |
|
|
|
|
|
INSTALLATION
The following items are supplied:
1MCS*E Series Power Supply
2 Spare fuses
2 Wire nuts
To install an MCS Series power supply, perform the following steps:
1.Decide where to install the unit.
2.Open the lid on the unit by removing the
3.Drill holes in the mounting surface. Use the unit as a template.
4.Attach the unit securely with four fasteners (not supplied) of the appropriate length. You can use fasteners up to
5.Punch out the necessary knockouts. (There are six knockout holes on the top and two on the bottom.)
6.Install
WARNING: Pelco will not be liable for any damages resulting from incorrect wiring or improper loading of an MCS*E Series power supply.
INPUT CONNECTIONS
Table B. Main Fuse Value Table
Fuse Location |
|
| ||
|
|
|
|
|
Main | 1A | 1.6A | 3A | 5A |
|
|
|
|
|
Individual Output | 1A | 3A | 3A | 3A |
|
|
|
|
|
1.Verify that the on/off switch inside the box is OFF.
2.Remove the high voltage compartment panel inside the box.
3.Attach the 120 input wires to the flying leads in the compartment with the supplied wire nuts (brown – AC line; blue – AC neutral).
4.Attach the input ground wire to the stud inside the compartment with the supplied washer and nut.
5.Replace the access panel.