Pelco C361M-A operation manual Wiring, Attachment

Page 4

WIRING

Make electrical connections as required for scanner operation. If required use the wire nuts (provided). Cable distances should not exceed the distances specified in Table A.

Refer to the following wiring diagrams (Figure 3) and select the correct diagram for your installation.

GLAND AND WIRING

ATTACHMENT

 

 

 

 

 

 

 

 

Figure 2. Bottom View, Wire

 

 

 

 

 

 

 

 

 

Attachment

 

120V MODEL

 

24V MODEL

 

230V MODEL

 

 

WITH CONTROLLER

 

 

WITH CONTROLLER

 

 

WITH CONTROLLER

 

 

 

BLU

COMMON

 

 

BLU

COMMON

 

 

WHT

COMMON

 

 

BRN

 

 

BRN

 

 

BLK

 

 

LEFT

 

 

LEFT

 

 

LEFT

CABLE

 

ORG

CABLE

 

ORG

CABLE

 

ORG

 

RIGHT

 

RIGHT

 

RIGHT

FROM

 

RED

AUTO

FROM

 

RED

AUTO

FROM

 

RED

AUTO

SCANNER

 

WHT

120 AC LO

SCANNER

 

WHT

24 AC LO

SCANNER

 

BLU

230 AC LO

 

GRN/YEL

 

GRN/YEL

 

GRN/YEL

 

 

GROUND

 

 

GROUND

 

 

GROUND

 

 

BLK

 

 

BLK

 

 

BRN

 

 

120 AC HI

 

 

24 AC HI

 

 

230 AC HI

 

WITHOUT CONTROLLER

 

WITHOUT CONTROLLER

 

WITHOUT CONTROLLER

 

 

 

 

 

 

 

WHT

 

GRN/YEL

 

CABLE

BLK

 

FROM

RED

 

 

BLU

 

SCANNER

 

BRN

 

 

ORG

120 AC LO

 

WHT

GROUND

 

GRN/YEL

 

 

BLK

 

120 AC HI

CABLE

 

AUTO

FROM

RED

 

 

BLU

 

120 AC LO

SCANNER

 

BRN

NOT USED

 

 

ORG

NOT USED

 

 

 

 

 

24 AC LO

 

BLU

GROUND

 

GRN/YEL

 

 

BRN

 

24 AC HI

CABLE

 

AUTO

FROM

RED

 

 

WHT

 

120 AC LO

SCANNER

 

ORG

NOT USED

 

 

BLK

NOT USED

 

 

 

 

 

230 AC LO GROUND 230 AC HI AUTO

120 AC LO NOT USED NOT USED

RANDOM MODE

RANDOM MODE

RANDOM MODE

 

WHT

 

GRN/YEL

 

CABLE

BLK

 

FROM

RED

 

 

 

 

ORG

 

 

 

SCANNER

 

 

 

BRN

 

 

 

 

 

 

BLU

 

 

120 AC LO

 

WHT

GROUND

 

GRN/YEL

 

120 AC HI

CABLE

BLK

 

 

FROM

RED

 

 

 

 

 

ORG

 

 

 

 

SCANNER

 

 

 

 

BRN

 

 

 

 

 

 

 

 

BLU

 

 

24 AC LO

 

BLU

GROUND

 

GRN/YEL

 

24 AC HI

CABLE

BRN

 

 

FROM

RED

 

 

 

 

 

BLK

 

 

 

 

SCANNER

 

 

 

 

ORG

 

 

 

 

 

 

 

 

WHT

 

 

230 AC LO GROUND 230 AC HI

00815

Figure 3. Wiring Diagrams - 120V, 24V and 230V Models

Table A. Maximum Operating Distances

Model

20 AWG

18 AWG

16 AWG

 

(0.5 mm2)

(1.0 mm2)

(1.5mm2)

 

 

 

 

PS20

2,300 ft

3,700 ft

5,900 ft

 

(701 m)

(1,127 m)

(1,798 m)

 

 

 

 

PS20-24

5,600 ft

9,000 ft

14,300 ft

 

(1,706 m)

(2,743 m)

(4,368 m)

 

 

 

 

PS20/23

1,400 ft

2,300 ft

3,600 ft

 

(426 m)

(701 m)

(1,097 m)

 

 

 

 

4

Pelco Manual C361M-A (8/02)

Image 4
Contents Page Important Safeguards and Warnings InstallationDescription ModelsPrepare Mounting Surface PS20 Surface Mount Template Pelco Manual C361M-A 8/02Wiring AttachmentMounting Speed SettingCAMERA/ENCLOSURE Mounting Limit Stop Adjustment Specifications MechanicalElectrical GeneralRegulatory Notices Revision History