Single Host With Two Hubs and Eight Controller Units Configured as Four Partner Groups
FIGURE 4-7 shows one application host connected through FC-AL cables to two hubs and to eight Sun StorEdge T3+ arrays, forming four partner groups. This configuration is the maximum allowed in a 72-inch cabinet. This configuration can be used for footprint and I/O throughput.
Note – This configuration is a recommended enterprise configuration for RAS functionality because the controller is not a single point of failure.
Note – There are no hub port position dependencies when connecting arrays to a hub. An array can be connected to any available port on the hub.
Each array needs to be assigned a unique target address using the port set command. These target addresses can be any number between 1 and 125. At the factory, the array target addresses are set starting with target address 1 for the bottom array and continuing to the top array. Use the port list command to verify that all arrays have a unique target address. Refer to Appendix A of the Sun StorEdge T3 and T3+ Array Administrator’s Guide for further details.
The following three parameters must be set on the master controller unit, as follows:
■mp_support = rw or mpxio
■cache mode = auto
■cache mirroring = auto
Note – For information on setting these parameters, refer to the Sun StorEdge T3 and T3+ Array Administrator’s Guide