Sun Microsystems T3 manual Glossary

Page 6

Administration Path 60

Connecting Partner Groups 60

Workgroup Configurations 62

Enterprise Configurations 63

Glossary 65

vi Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001

Image 6
Contents Sun StorEdge T3 and T3+ Array Configuration Guide Please Recycle Contents Configuring Partner Groups Host Connections Glossary Figures Sun StorEdge T3 Array Controller Card and Interconnect Cards Preface Before You Read This Book How This Book Is OrganizedUsing Unix Commands Typographic ConventionsShell Prompts Related DocumentationAccessing Sun Documentation Online Sun Welcomes Your CommentsArray Configuration Overview Product DescriptionController Card 1Sun StorEdge T3 Array Controller Card and Ports Interconnect Cards 2Sun StorEdge T3+ Array Controller Card and PortsInterconnect cards Output Input Array Configurations 4Workgroup Configuration5Enterprise Configuration Configuration Guidelines Restrictions Configuration Recommendations Supported PlatformsSupported Software Sun Cluster SupportArray Configuration Overview Sun StorEdge T3 and T3+ Array Configuration Guide August Configuring Global Parameters CacheConfiguring Cache for Performance and Redundancy Configuring Data Block Size Selecting a Data Block SizeLogical Volumes Configuring Cache AllocationEnabling Mirrored Cache Guidelines for Configuring Logical Volumes Determining How Many Logical Volumes You NeedDetermining Which RAID Level You Need Creating and Labeling a Logical Volume Setting the LUN Reconstruction RateUsing RAID Levels to Configure Redundancy RAID Configuring RAID Levels Configuring Partner Groups Understanding Partner Groups1Sun StorEdge T3 Array Partner Group How Partner Groups Work Creating Partner Groups Configuration Examples Direct Host ConnectionSingle Host With One Controller Unit 1Single Host Connected to One Controller UnitConfiguration Examples Host Multipathing Management Software LUNFC-AL Sun StorEdge T3 and T3+ Array Configuration Guide August FC-AL HBA LAN Hub Host Connection Application host HBA Sun StorEdge T3 and T3+ Array Configuration Guide August Management host Cache mode = auto Cache mirroring = auto Dual Hosts With Two Hubs and Four Controller UnitsPort Dual Hosts With Two Hubs and Eight Controller Units Controller unit Hub Sun StorEdge T3 and T3+ Array Configuration Guide August HBA Sun StorEdge T3 and T3+ Array Configuration Guide August Hub Application host Switch Host Connection Dual Hosts With Two Switches and Two Controller UnitsSwitch Dual Hosts With Two Switches and Eight Controller Units FC-AL LAN Sun StorEdge T3 and T3+ Array Configuration Guide August Host Connections Sun Enterprise SBus+ and Graphics+ I/O Boards System RequirementsSun StorEdge PCI FC-100 Host Bus Adapter 2Sun StorEdge PCI FC-100 Host Bus AdapterSun StorEdge SBus FC-100 Host Bus Adapter 3Sun StorEdge SBus FC-100 Host Bus AdapterSun StorEdge PCI Single Fibre Channel Network Adapter 4Sun StorEdge PCI Single Fibre Channel Network AdapterSun StorEdge PCI Dual Fibre Channel Network Adapter 5Sun StorEdge PCI Dual Fibre Channel Network AdapterSun StorEdge CompactPCI Dual Fibre Channel Network Adapter 6Sun StorEdge CompactPCI Dual Fibre Channel Network AdapterSun StorEdge T3 and T3+ Array Configuration Guide August Overview of Array Cabling Data PathAdministration Path Connecting Partner GroupsLC-SFF Workgroup Configurations 3Array Workgroup ConfigurationEnterprise Configurations 4Enterprise ConfigurationSun StorEdge T3 and T3+ Array Configuration Guide August Administrative GlossaryCommand-line interface Flash memory device Light-emitting diode Multi-initiator Reverse address resolution protocol Workgroup Sun StorEdge T3 and T3+ Array Configuration Guide August Index HBA RAID Sun StorEdge T3 and T3+ Array Configuration Guide August
Related manuals
Manual 124 pages 50.98 Kb