Sun Microsystems A3500 manual 11x5 Module ID Switch Settings

Page 22

2.1.2.2Module ID Switch

Ensure that the module IDs for the StorEdge D1000 disk arrays are set according to TABLE 2-1.

TABLE 2-11x5 Module ID Switch Settings

Disk array number

Module ID setting

 

 

 

5

(Top)

5

4

 

4

3

 

3

2

 

2

1

(Bottom)

1

 

 

 

2.1.2.3SCSI Jumper Cables and Terminators

All disk arrays in this configuration should have SCSI jumper cables between the middle SCSI connectors (IN/OUT-1 and IN/OUT-2) and a differential SCSI terminator in the far right SCSI connector (IN/OUT-2). This configuration is shown in FIGURE 2-15.

2-6Sun StorEdge A3500 Hardware Configuration Guide • September 1998

Image 22
Contents Sun StorEdge A3500 Hardware Configuration Guide Page Contents Iv Sun StorEdge A3500 Hardware Configuration Guide September Using Unix Commands PrefaceTable P-1Typographic Conventions Typographic ConventionsShell Prompts Table P-2Shell PromptsSun Welcomes Your Comments Related DocumentationSun Documentation on the Web Table P-3Related DocumentationPage Host Connections Configuration Guidelines Supported Host Configurations Single HostDaisy Chain Independent Controller 4Two-Node Multi-Initiator Configuration Multi-InitiatorUltra 2 Host System-Power Connection Requirement 5AC Power Sequencers-Ultra 2 Power ConnectorGain access to the AC power sequencers StorEdge A3500 Configurations StorEdge D1000 Disk Array Settings Rear1 1x2 Configuration Option Switch1x2 Module ID Switch Settings Module ID SwitchScsi Jumper Cables and Terminators 2 1x5 Configuration 51x5 Option Switch Settings for StorEdge D1000 Disk Array11x5 Module ID Switch Settings 3 2x7 Configuration 82x7 Option Switch Settings for StorEdge D1000 Disk Array22x7 Module ID Switch Settings 33x15 Module ID Switch Settings 4 3x15 Configuration43x15 Module ID Switch Settings 10Sun StorEdge A3500 Hardware Configuration Guide September Cable Lengths 1x2 CablingScsi Cabling 5Controller Module aScsi Connections 11One A3000 Controller Module and Two D1000 Disk Arrays ScsiPower Connections 1x5 Cabling 6Controller Module aDifferential Scsi terminator Scsi jumper cable Rear view R6R4 Front sequencer R1&R2 Rear sequencer L1&L2 7Controller Module a 2x7 Cabling8Controller Module B Controller Module a Controller Module B Front Sequencer Rear 3x15 Cabling 10Controller Module B Controller Module a11Controller Module C Scsi Connections for Controller Module a 3x15 Controller Module aScsi Connections for Controller Module B 203x15 Controller Module BScsi Connections for Controller Module C 213x15 Controller Module CConnecting to AC Power Source Power Sequencer Interconnections2x71x8 Phase a Power connections for the 1x8 cabinet are shown in Figure 28Sun StorEdge A3500 Hardware Configuration Guide September