FIGURE 2-11
2.1.1.2Module ID Switch
Ensure that the module IDs for the StorEdge D1000 disk arrays are set according to .
1x2 Module ID Switch Settings
Disk array number | Module ID setting |
| | |
2 | (Top) | 2 |
1 | (Bottom) | 1 |
| | |
Note –Since the top and bottom disk arrays are split between one controller module, the Module IDs will overlap. This may result in error messages while the host system is booting. The ASC/ASCQ codes for this error is 98/01 and the Sense Key is 6. These error messages are information only and will not impact system performance.
2.1.1.3SCSI Jumper Cables and Terminators
The disk arrays should have differential SCSI terminators on the inside IN/OUT-1 and IN/OUT-2 SCSI connectors. This configuration is shown in
2-4Sun StorEdge A3500 Hardware Configuration Guide • September 1998