Sun Microsystems A3500FC manual Setting the Loop ID

Page 31

2.3Setting the Loop ID

This section explains how to set the loop ID of a controller that is connected to a hub.

Tools and equipment needed:

Needlenose pliers

Jumpers (supplied with the StorEdge A3500/A3500FC unit)

Antistatic wrist strap

Every device attached to a SCSI or FC-AL bus must have a unique controller module ID number in order to communicate. The factory default ID settings for controller A and B are ID 5 and ID 4, respectively.

Note Do not configure more than four controller modules on the same loop.

1.Locate the 16 pins on the rear of the FC-AL controller module (FIGURE 2-8).

The eight pins on the right determine the host ID for controller 1(A); the pins on the left determine the ID for controller 2(B).

2.Wearing the antistatic wrist strap, install jumpers on the pins as shown in

FIGURE 2-8.

If necessary, use the needlenose pliers to remove the jumpers.

Chapter 2 FC-AL Host Connections 2-13

Image 31
Contents Sun StorEdge A3500/A3500FC Hardware Configuration Guide Please Recycle Contents Sun StorEdge A3500/A3500FC Configurations Sun StorEdge A3500 and A3500FCSpecifications Page How This Book Is Organized Using Unix CommandsShell Prompts Typographic ConventionsTable P-3Related Documentation Related DocumentationSun Welcomes Your Comments Sun Documentation on the WebScsi Host Connections Configuration Guidelines Single Host Connected to One Controller Module Supported Scsi Host Configurations2Two Controller Modules Daisy-Chained to One Host Two Controller Modules Daisy-Chained to One Host3Independent Controller Module Connected to Two Hosts Independent Controller Module Connected to Two HostsMulti-Host 4Two-Node Multi-Host ConfigurationUltra 2 Host System Power Connection Requirement Gain access to the AC power sequencers FC-AL Host Connections Differential Scsi terminators-HOST Supported FC-AL Host Configurations 2One Host Connected to One Controller Module Independent Controller Module Connected to Two Hosts 4Single Host Connected to One Controller Module Using Hubs Single Host Connected to One Controller Module Using HubsSingle Host Connected to Two Controller Modules Using Hubs 5Single Host Connected to Two Controller Modules Using Hubs FC-AL Host Connections Host Multi-Host Host Host adapter Setting the Loop ID Controller B 2 1 Dec Sun StorEdge A3500/A3500FC Configurations 1StorEdge D1000 Disk Array StorEdge D1000 Disk Array SettingsOption Switch 1 1x2 ConfigurationModule ID Switch 51x5 Option Switch Settings for StorEdge D1000 Disk Array 2 1x5 Configuration21x5 Module ID Switch Settings 82x7 Option Switch Settings for StorEdge D1000 Disk Array 3 2x7 Configuration32x7 Module ID Switch Settings 4 3x15 Configuration Scsi Jumper Cables and Terminators Driveside Scsi Connections 1x2 Cables and ConnectionsTerminator Power Connections 1x5 Cables and Connections Scsi jumper cable 16shows the power connections for 1x5 configurations Scsi Cable Lengths 2x7 Cables and ConnectionsController Module a 16shows the power connections for 2x7 configurations 3x15 Cables and Connections 11Controller Module B 3x15 Configuration Cables12Controller Module C 3x15 Configuration Cables 19shows the Scsi connections for controller module a 20shows the Scsi connections for controller module B 21shows the Scsi connections for controller module C Connections to AC Power Sources Connections Between Power Sequencers23Power Connections to Avoid Different Phases Power Connections for Expansion CabinetsPower connections for the 1x8 expansion cabinet are shown Page Initial Cold Start Surge Current Specifications Sun StorEdge A3500 and A3500FC SpecificationsTable A-2Cabinet Surge Current Specifications