Sun Microsystems 1800 manual Installation Methods, Local Installation

Page 72

Installation Methods

The Netra ft 1800 supports two types of installation: local, from a local CD-ROM drive; or network, from a machine set up as a Solaris installation server. The requirements for these two types of installation are described in the following subsections.

You must install the Sun StorEdge Volume Manager package when the Netra ft 1800 installation is complete in order to implement fault tolerant operation. See Chapter 6 “Installing and Configuring Sun StorEdge Volume Manager” for more details.

You should install patches after the Netra ft 1800 software installation. Recommended Solaris patches are included on the Netra ft 1800 Installation CD- ROM. Any recommended patches should be installed immediately after the reboot at the end of the installation.

The local and network installation procedures differ only in their initial steps. Otherwise, the procedure is the same for both types of installation.

Note Inadvertent keyboard use during installation can abort installation.

Local Installation

To perform a local installation of the Netra ft 1800 software, you must have an RMM module that contains a CD-ROM drive in slot A-RMMor B-RMMof the Netra ft 1800 to be installed.

Local installation involves booting the Netra ft 1800 from one of its CD-ROM drives while an installation CD-ROM is in the drive.

Note The CD-ROM cannot be loaded into the CD-ROM drive unless the drive is powered on. Do not attempt to load the CD-ROM unless the module’s Power LED is lit.

58 Netra ft 1800 Installation Guide • February 1999

Image 72
Contents Netra ft 1800 Installation Guide Please Recycle Contents Electrical Supply Installation Installing and Configuring Sun StorEdge Volume Manager IndexVi Netra ft 1800 Installation Guide February Figures Circuit Breakers for Dual Power Rails Tables Netra ft 1800 Installation Guide February Who Should Use This Book How This Book Is OrganizedRelated Books What Typographic Changes MeanTable P-1Typographic conventions Shell Prompts in Command Examples SymbolsTable P-2Shell prompts Sun Documentation on the Web Sun Welcomes Your CommentsElectrical Supply Considerations Environmental ConsiderationsDimensions Airflow Consideration when Mounting in the Equipment FrameBefore Installation Minimum 2U 90 mm gap CAF Mounting Requirements 1Mounting Hole Pattern Dimensions LoadingVertical space Safety DepthUnshipping and Mounting the System ToolsNetra ft 1800 Installation Guide February To Unship and Mount the System 1Shipping Brackets and Sacrificial PlinthRefer to Removing and Installing Modules on Mounting Flanges Inch Mountings119-inch Mounting Flange Kit 2Location Matrix For Mounting Flange Screws 19-inch rack Support Rail and Fixings 19-inch Rack 2Support Rail Screw Hole LocationsChassis Support rail Screw Spacer 619-inch Rack Mounting Flange Kit Inch, 24-inch and 600mm Mountings 323-inch, 24-inch and 600mm Mounting Flange Kits723-inch Rack Mounting Flange Kit 824-inch Rack Mounting Flange Kit 9600-mm Rack Mounting Flange Kit 10Cable Bracket Assembly Cable Bracket AssembliesRemoving and Installing Modules Module Injector/Ejector MechanismsTo Remove a Module 11Module Injector/ejector LeverCPUset Modules 12Removing a CPUset Module CAF Modules 13Removing a CAFPCI Modules 14Removing a PCI Card Carrier15Removing a Power Supply PSU ModulesTo Replace a Module Replacing an RMMTo Remove the RMM Slide the module into its slot but not fully home16Removing an RMM Module Replacing a Disk Chassis To Replace the RMMTo Remove the Disk Chassis 17Removing a Disk Drive To Replace the Disk Chassis 18Removing a DSK ModuleFlexible Module Cabling 19Cable Management ShelfInstalling the Filter Trays To Install the Filter TraysIt is unimportant which way up the trays are fitted CAF External I/O Connections External I/O Connections on CAF Module4Console Connector Pinout System Console Terminal Connections5Console and Modem Port Parameters Modem Port Connections 6Modem Port PinoutAlarms Port Connections 7Alarms Port PinoutNetra ft 1800 Installation Guide February Electrical Supply Installation System SwitchDC Source Site Requirements Overcurrent Protection Requirements1Overcurrent Protection Requirements Electrical Supply Installation RTN B Return a 48V supply CB CB RTN B RTN a -48V a -48V B Return B Required Connection Materials DC Supply and Ground ConductorDual Grounding Environment To Connect the Ground LeadNetra ft 1800 Installation Guide February Connecting the Power Leads 4Power Inlet FilterTo Assemble the Power Inlet and Leads Strip 9mm of insulation from boths ends of each power leadRefer to Figure Secure the cables using adequate strain relief Powering on the System To Power On the SystemPush the other On system switch on the other CAF front panel Netra ft 1800 Install Media Disk Space RequirementInstallation Methods Local InstallationNetwork Installation To Install the Software Before You StartEstablish the following Boot the system For local installation, type For network installation, go to the OBP ok prompt and typeInstall the Solaris operating environment Reboot the system by typing 1Suggested Disk LayoutFinishing Installation Setting up Access to Netra ft 1800 CMS UtilitiesSetting the Manpath Variable Install the appropriate patchesSetenv Manpath $MANPATH/opt/SUNWftm Installing and Configuring Sun StorEdge Volume Manager Before You Install Sun StorEdge Volume ManagerPress q twice to exit cmsconfig Locate the HDD modules in the listInstalling the Volume Manager Software Running the InstallationMounting the CD-ROM Manually Setting up the Volume Manager Environment Setting Default Volume CreationDealing with Stale Boot Disks Initializing the Volume Manager Enabling Recovery Behavior and Boot Disk DetectionSetting up Boot Disks Setting up Other Disks Configuring StorageTo Add a New Disk Add the disk to a disk groupBoot Disk Aliases Index Netra ft 1800 Installation Guide February Vxdiskadm, configure disks in Volume Manager Weight Empty chassis, 6 maximum, 2 removable modules

1800 specifications

Sun Microsystems, founded in 1982, unveiled an array of innovative products over the years, among which the Sun-1 workstation and later the Sun-1800 series were significant contributions to the technology landscape. Designed specifically for engineering, graphics, and computing tasks, the Sun-1800 series emerged during a period when workstations were essential for high-performance computing applications.

The Sun-1800 series was powered by the SPARC architecture, which became a hallmark of Sun Microsystems' technological advancement. SPARC, an acronym for Scalable Processor Architecture, allowed the system to achieve high levels of performance and efficiency, positioning it well against competitors in the workstation market. The SPARC processors used in the Sun-1800 series enabled faster computation and multitasking, making it well-suited for scientific applications, computer-aided design (CAD), and complex data analyses.

One of the standout features of the Sun-1800 series was its expansive memory capabilities. Supporting configurations that could house up to 128 megabytes of RAM, the workstations were excellent for handling large datasets that were prevalent in research and corporate environments. This high memory capacity, combined with the efficient use of the SPARC architecture, granted users access to significant computational power, which was crucial for multitasking in complex job environments.

The Sun-1800 series also emphasized networking capabilities, with integrated Ethernet support. This allowed users to seamlessly connect their workstations into local area networks, facilitating collaborative projects and data sharing among teams. The use of the Solaris operating system, which was based on UNIX, also provided a robust and stable environment for enterprise applications, making the Sun-1800 ideal for business-critical applications.

Moreover, the system was designed to support various programming languages and development tools, attracting engineers, scientists, and software developers alike. Sun Microsystems also focused on providing high-quality graphics support, with advanced graphical capabilities that enabled users to engage in advanced visualization tasks, such as 3D modeling.

In summary, the Sun Microsystems 1800 series stands out for its powerful SPARC architecture, impressive memory capacity, integrated networking, and robust graphic capabilities. These characteristics, combined with the reliability of the Solaris operating system, positioned the Sun-1800 as a favored choice among professionals in engineering and scientific fields, shaping the future of workstation computing.