TABLE 5 defines the lance_mode and ipg0 parameters.

TABLE 5 Parameters Defining lance_mode and ipg0

Parameter

Values and Descriptions

 

 

 

lance_mode

0 =

lance_mode disabled

 

1 =

lance_mode enabled (default)

ipg0

0 to 30 = Additional IPG before transmitting

 

a packet (after receiving a packet)

 

 

 

Operational Mode Parameters

TABLE 6 describes the operational mode parameters and their default values.

TABLE 6 Operational Mode Parameters

ParameterValues and Description

adv_1000autoneg_cap Local PCS capability advertised by the hardware

 

0

= Forced mode

 

1

= Autonegotiation (default)

adv_1000fdx_cap

Local PCS capability advertised by the hardware

 

0

= Not 1000 Mbits/sec full duplex capable

 

1

= 1000 Mbits/sec full duplex capable (default)

adv_1000hdx_cap

Local PCS capability advertised by the hardware

 

0

= Not 1000 Mbits/sec half duplex capable

 

1

= 1000 Mbits/sec half duplex capable (default)

adv_pauseTX

Local PCS capability advertised by the hardware

 

0

= Not Pause TX capable (default)

 

1

= Pause TX capable

adv_pauseRX

Local PCS capability advertised by the hardware

 

0

= Not Pause RX capable

 

1

= Pause RX capable (default)

 

 

 

8 Platform Notes: The Sun GigabitEthernet Device Driver • March 1999

Image 12
Contents Solaris Please Recycle Contents To Use the ndd Utility in Non-Interactive Mode Installing the Driver Software To Install the Driver SoftwareBecome superuser Set Up the Software on Solaris Systems Install the software# grep ge /etc/pathtoinst /pci@1f,4000/pci@1/network@1 1 ge Configuring the Driver Parameters GigabitEthernet MACDriver Parameter Values and Definitions Ge Driver Parameters, Status, and DescriptionsDefining the Current Status Flow Control ParametersRead-Only Parameters Defining the Current Status Read-Write Flow Control Parameters Values and DescriptionsInterpacket Gap Parameters Operational Mode Parameters Operational Mode ParametersParameters Defining lancemode and ipg0 Reporting Local PCS Capabilities Reporting the Link Partner CapabilitiesRead-Only PCS Capabilities Read-Only Link Partner CapabilitiesSetting ge Driver Parameters Setting Parameters Using the ndd UtilityTo Specify the Device Instance for the ndd Utility Non-Interactive and Interactive ModesUse the instance number to select the device To Use the ndd Utility in Non-Interactive Mode To Use the ndd Utility in Interactive ModeTo View the ge Driver Parameters To modify a parameter value, use the -setoptionAutonegotiation Mode To Set Autonegotiation to Off Forced ModeSetting Parameters Using the ge.conf File Understanding the ge.conf FileTo Set Parameters Using the ge.conf File on an SBus adapter Network Configuration To Configure the Host FilesTo Set Parameters Using the ge.conf File on a PCI adapter Etc/hostname.ge1 To Set Up a Diskless Client on a Server # grep clientname /etc/bootparams At the ok prompt, type

805-7945-10 specifications

Sun Microsystems 805-7945-10 is a notable component from the Sun Microsystems lineup, particularly recognized for its role in the high-performance computing and networking space. This product is often associated with Sun's commitment to delivering robust solutions for enterprise environments. The 805-7945-10 is primarily a part of the Sun Fire V20z server systems, designed to meet the growing demands of data centers needing powerful processing capabilities.

One of the main features of the 805-7945-10 is its support for dual-core processors, specifically the AMD Opteron line. This multi-core architecture allows for enhanced multitasking and parallel processing, making it an ideal choice for server applications that require handling multiple processes simultaneously. With a maximum configuration supporting up to 64GB of RAM, this server leverages memory availability to boost performance in memory-intensive applications.

The Sun 805-7945-10 also emphasizes its compatibility with various operating systems, including Solaris, Linux, and Windows. This flexibility ensures that businesses can integrate the server into their existing infrastructure without significant hurdles. Furthermore, the 805-7945-10 boasts substantial storage options, supporting multiple RAID configurations which provide data redundancy and improved performance.

In terms of technologies, the 805-7945-10 incorporates advanced thermal management solutions which optimize cooling efficiency, thereby extending the lifespan of the components within the server. This thermal reliability is crucial for data centers that operate continuously, ensuring that high processing loads do not lead to overheating.

Another important characteristic of the Sun 805-7945-10 is its networking capabilities. The server typically includes multiple Ethernet ports, allowing for high-speed data transfers and enhanced network reliability. This design caters to the needs of enterprises that rely on stable and fast connectivity for their applications.

The 805-7945-10 also features comprehensive management tools that facilitate remote monitoring and administration, empowering IT teams to manage the system effectively without needing to be physically on-site.

In conclusion, the Sun Microsystems 805-7945-10 stands out due to its high-performance multi-core processing, flexible operating system support, robust storage options, and efficient thermal management. These features, combined with its strong networking capabilities, make it a valuable asset for modern data centers and enterprises looking for reliable server solutions.