Sun Microsystems 805-7945-10 manual To Use the ndd Utility in Non-Interactive Mode

Page 16

To Use the ndd Utility in Non-Interactive Mode

This section describes how to modify and to display parameter values.

1.To modify a parameter value, use the -setoption.

If you invoke the ndd utility with the -setoption, the utility passes value, which must be specified down to the named /dev/ge driver instance, and assigns it to the parameter:

#ndd -set /dev/ge parameter value

2.To display the value of a parameter, specify the parameter name (and omit the value).

When you omit the -setoption, a query operation is assumed and the utility queries the named driver instance, retrieves the value associated with the specified parameter, and prints it:

#ndd /dev/ge parameter

To Use the ndd Utility in Interactive Mode

To modify a parameter value in interactive mode, specify ndd /dev/ge, as shown below.

The ndd utility then prompts you for the name of the parameter:

#ndd /dev/ge

name to get/set? (Enter the parameter name or ? to view all parameters)

To View the ge Driver Parameters

After entering the parameter name, the ndd utility prompts you for the parameter value (see TABLE 1 through TABLE 8).

12 Platform Notes: The Sun GigabitEthernet Device Driver • March 1999

Image 16
Contents Solaris Please Recycle Contents To Use the ndd Utility in Non-Interactive Mode To Install the Driver Software Installing the Driver SoftwareBecome superuser Set Up the Software on Solaris Systems Install the software# grep ge /etc/pathtoinst /pci@1f,4000/pci@1/network@1 1 ge Configuring the Driver Parameters GigabitEthernet MACDriver Parameter Values and Definitions Ge Driver Parameters, Status, and DescriptionsDefining the Current Status Flow Control ParametersRead-Only Parameters Defining the Current Status Read-Write Flow Control Parameters Values and DescriptionsInterpacket Gap Parameters Operational Mode Parameters Operational Mode ParametersParameters Defining lancemode and ipg0 Reporting Local PCS Capabilities Reporting the Link Partner CapabilitiesRead-Only PCS Capabilities Read-Only Link Partner CapabilitiesSetting ge Driver Parameters Setting Parameters Using the ndd UtilityNon-Interactive and Interactive Modes To Specify the Device Instance for the ndd UtilityUse the instance number to select the device To Use the ndd Utility in Non-Interactive Mode To Use the ndd Utility in Interactive ModeTo View the ge Driver Parameters To modify a parameter value, use the -setoptionAutonegotiation Mode To Set Autonegotiation to Off Forced ModeSetting Parameters Using the ge.conf File Understanding the ge.conf FileTo Set Parameters Using the ge.conf File on an SBus adapter To Configure the Host Files Network ConfigurationTo Set Parameters Using the ge.conf File on a PCI adapter Etc/hostname.ge1 To Set Up a Diskless Client on a Server # grep clientname /etc/bootparams At the ok prompt, type

805-7945-10 specifications

Sun Microsystems 805-7945-10 is a notable component from the Sun Microsystems lineup, particularly recognized for its role in the high-performance computing and networking space. This product is often associated with Sun's commitment to delivering robust solutions for enterprise environments. The 805-7945-10 is primarily a part of the Sun Fire V20z server systems, designed to meet the growing demands of data centers needing powerful processing capabilities.

One of the main features of the 805-7945-10 is its support for dual-core processors, specifically the AMD Opteron line. This multi-core architecture allows for enhanced multitasking and parallel processing, making it an ideal choice for server applications that require handling multiple processes simultaneously. With a maximum configuration supporting up to 64GB of RAM, this server leverages memory availability to boost performance in memory-intensive applications.

The Sun 805-7945-10 also emphasizes its compatibility with various operating systems, including Solaris, Linux, and Windows. This flexibility ensures that businesses can integrate the server into their existing infrastructure without significant hurdles. Furthermore, the 805-7945-10 boasts substantial storage options, supporting multiple RAID configurations which provide data redundancy and improved performance.

In terms of technologies, the 805-7945-10 incorporates advanced thermal management solutions which optimize cooling efficiency, thereby extending the lifespan of the components within the server. This thermal reliability is crucial for data centers that operate continuously, ensuring that high processing loads do not lead to overheating.

Another important characteristic of the Sun 805-7945-10 is its networking capabilities. The server typically includes multiple Ethernet ports, allowing for high-speed data transfers and enhanced network reliability. This design caters to the needs of enterprises that rely on stable and fast connectivity for their applications.

The 805-7945-10 also features comprehensive management tools that facilitate remote monitoring and administration, empowering IT teams to manage the system effectively without needing to be physically on-site.

In conclusion, the Sun Microsystems 805-7945-10 stands out due to its high-performance multi-core processing, flexible operating system support, robust storage options, and efficient thermal management. These features, combined with its strong networking capabilities, make it a valuable asset for modern data centers and enterprises looking for reliable server solutions.