You can use the ILOM web interface or ILOM CLI to verify
Using the ILOM Web Interface
1.Log in to the ILOM web interface using the IP address of the active Chassis Monitoring Module.
The first page of the ILOM web interface is displayed.
2.In the left navigation pane, select CMM (Chassis Monitoring Module). The ILOM Version Information page is displayed.
3.Select the System Information tab, and then the Components tab. The Component Management page is displayed.
4.Verify that the selected NEM has returned the expected feedback. See “To Verify NEM Status” on page 16.
Using the ILOM CLI
1.Log in to the ILOM CLI of the active Chassis Monitoring Module.
2.For a list of components in your system, type: show /CH
3.To verify that the NEM Ready to Remove status has changed to Not Ready, type: show /CH/component prepare_to_remove_status
The system returns:
prepare_to_remove_status = Not Ready
4.Verify that the selected NEM has returned the expected feedback. See “To Verify NEM Status” on page 16.
▼To Verify NEM Status
See TABLE
1.Check the following LEDs to verify that the NEM is ready for a