TROUBLESHOOTING

PROBLEM:

Keyboard Errors

 

SOLUTION:

Check cable connections on each CPU and the switch.

PROBLEM:

No Video

 

SOLUTION:

Check cable connections on each CPU and the switch. Verify that keyboard and video connect from each CPU

 

to matching ports. After reconnecting, CPU may need to be re-booted in order to sense the monitor connection.

PROBLEM:

No OSD

 

SOLUTION:

The administrator may have configured the unit as a slave instead of stand-alone switch. OSD will not work

 

when a NODEMUX is configured as a slave.

To reconfigure the switch to a stand-alone configuration, see

 

RS232 Control , "CF" command on page 20.

 

 

BE SURE TO READ WARNING BEFORE USING THIS COMMAND.

PROBLEM:

No Keyboard or Mouse

 

SOLUTION:

Shut down CPU's. Power cycle the switch.

Turn on CPU's.

DEFAULT PASSWORD RESET

In the event the Administrator password is lost or forgotten, the password can be reset to the default password of ADMINISTRATOR. Figure 26 shows the location of the password reset button.

Rear View

RACKMUX-V15-8UNV

Front View of NODEMUX inside RACKMUX-V15-8UNV

NTI R

Network Technologies Inc

TM

Password Reset Button- Press to reset administrator password to default "ADMINISTRATOR"

Figure 26- Locating the password reset button

To reset the password;

1.Turn the power OFF to the NODEMUX.

2.Press and hold the password reset button. (Stick something non-conductive into the small opening to depress the button inside.)

3.Turn the power ON to the NODEMUX.

4.Release the password reset button.

For instruction on how to change the default administrator password, see page 10.

29

Image 33
Contents RACKMUX-V15-4UNV Trademark Table of Contents Index Warranty Information Troubleshooting Default Password ResetModels Available FeaturesTypes of CPUs Supported OptionMaterials Set of 2 cables for each CPU being connected to the switch17 18 19 20 21 Rear View Installation Rack Mounting InstructionsConnect The Cables 13W3M-15HDF Pin miniDINPower-Up Sequence IEC Power CordIEC Connectxor Enabling the Security Feature Using the RackmuxKeyboard Control OSD ControlUser Login Mode Administration ModeAdditional Modes Available With Security Exit Administration Mode Return to previous mode Esc Switch ConfigurationAdministrator Password User Name ListKeystroke Ctrl + a Ctrl + E Ctrl + P Esc System Access List User Access FunctionsCommand Mode Keystroke Enter EscType to a CPU To exit Command Mode, either hold down any Scan Mode Broadcast ModeNormal Mode Edit ModeSearch Mode Edit Mode Contd FunctionEsc Enter Maintenance Mode Activate security featuresFunctionKeystroke Help Mode RS232 Connections and ConfigurationRS232 Connector DB-9 Female RS232 ControlConfiguration Baud RateLoop Back Wiring Schematic of Matrix-Y-1 cable Command ProtocolExit Switch Configuration Mode Unit AddressResponse Format RS AacrFormat CS AA,XX,YYCR Format CA AA,XXCRFormat Standard Controls Display FunctionsOSD Control Menu OSD Main MenuBrightness/Contrast Menu Color MenuPosition Menu OSD Image can be moved to different points on the display Setup MenuKeyboard Functions Function Key to enable additional key functionsRACKMUX-V15-x Function Key OperationKeys of the Number Pad Number PadAdditional multi-function keys Other Functions of the Fn KeyS. English keyboard with numeric keypad Numeric Keypad OptionKeyboard-To-Computer Translation Keyboard FeaturesTranslation Capabilities Translation TablesDefault Password Reset TroubleshootingGeneral Specs RACKMUX-KVM Drawer Standard SpecificationsLCD Display Controller VGA -15Keyboard Warranty InformationTouchpad Index

RACKMUX-V17-4UNV, RACKMUX-V17-8UNV, RACKMUX-V15-8UNV, RACKMUX-V15-4UNV specifications

Network technologies have seen significant advancements to meet the increasing demand for efficient data management and distribution. Among the prominent solutions in this arena are the RACKMUX-V15-4UNV, RACKMUX-V15-8UNV, RACKMUX-V17-8UNV, and RACKMUX-V17-4UNV. These devices play a critical role in modern networking by providing robust matrix switching capabilities that can accommodate various needs across different environments.

The RACKMUX-V15-4UNV is designed for compact networking setups. This unit features four universal inputs, allowing for seamless integration with multiple devices. Its compact 1U design makes it particularly suitable for environments where space is at a premium, such as data centers and server rooms. The technology supports high-bandwidth data throughput, ensuring fast and efficient data transfers. Moreover, it offers easy monitoring and control through an intuitive user interface, simplifying management for network operators.

Moving to the RACKMUX-V15-8UNV, this model expands upon its predecessor by supporting up to eight universal inputs. It's ideal for larger networking scenarios, providing greater flexibility and scalability. The device comes equipped with advanced signal processing capabilities, enabling it to handle diverse formats without compromising on performance. It also features hot-swappable architecture, ensuring that operators can replace or upgrade components without affecting system uptime.

The RACKMUX-V17-4UNV introduces enhanced functionality with its four universal inputs, incorporating cutting-edge technology for an even more efficient switching process. The key distinguishing feature of the V17 line is its improved power management system, allowing for reduced energy consumption without sacrificing performance. This model is aimed at eco-conscious organizations seeking to lower their carbon footprint while still maintaining high-quality network performance.

Lastly, the RACKMUX-V17-8UNV raises the bar further by providing eight universal inputs alongside advanced features that optimize operational capabilities. This model utilizes the latest in networking protocols, ensuring compatibility with various emerging technologies. Its robust build quality also ensures reliability, reducing maintenance needs and increasing longevity.

Each of these devices reflects the growing need for adaptable and efficient network technologies. Their main features, including universal input support, enhanced signal processing, compact designs, and energy management, make the RACKMUX ranges an excellent choice for organizations looking to optimize their network infrastructure. With ongoing advancements, these models will continue to adapt to the evolving landscape of network technology, offering robust, reliable solutions for years to come.