Network Technologies MAN027 manual Command Mode, Default Value Reset, Function, Keystroke

Page 8

Command Mode

Function:

Increment Port

Decrement Port

Keystroke:

I

or

(select the next higher port

ex. 01

02)

D

or

(select the next lower port

ex. 02

01)

or

+

-

KEY SYMBOLS LEGEND:

PRESS EITHER KEY

CHORDED SEQUENCE- PRESS CONSECUTIVELY AND KEEP KEYS PRESSED UNTIL ALL ARE PRESSED.

PRESS CONSECUTIVELY

Toggle Scan Mode ON and OFF

S

(When toggled to ON, Scan Mode will be indicated the LED for only the active CPU

flashing ON and OFF .)

 

Sets scan time-out

T

-

(0-2)

-

(0-9)

-

(0-9)

(xxx from 002 to 255. ie. t002

would set the time-out period

period for each port.

x

x

x

for 2 seconds)

Toggle Broadcast Mode ON and OFF

B

(When toggled to ON, Broadcast Mode will be indicated by both LEDs cycling alternately

ON and OFF in rapid intervals.)

Selects a specific port

Select a different control key combination

Select a specific country code for the keyboard

P - 0 -

C - x

L - x -

(1-2)

(P0x would be P01 or P02.)

x

 

x = the desired key (This will replace the Ctrl + ` sequence to enter Command Mode)

x

(Lxx would be L00-L34, see Country Codes Table on page 9)

Print the code version to a text editor

V

(This will print the version of the code in the KEEMUX-USBV-2U switch to a text editor

window for use when troubleshooting the switch)

Configure port to connect To a MAC CPU

Configure port to connect To a WINDOWS or SUN CPU

Exit Command Mode

M

+

x

(x= 1 or 2 <M> + <1> will enable function on Port 1

<M> + <2> will enable function on Port 2. Keyboard

 

LED's will flash once to confirm command. )

W

+

x

(x= 1 or 2 <W> + <1> will disable function on Port 1

<W> + <2> will disable function on Port 2. Keyboard

 

LED's will flash once to confirm command. )

 

 

 

 

 

Esc

 

 

Note: The user must exit Command

 

 

 

Mode to use the CPU(s) in the

 

 

 

 

selected mode.

 

 

 

 

 

 

 

Default Value Reset

Default factory-set values for Command Mode entry key, Scan dwell time and country code can be restored by following this procedure:

1.Disconnect power from the UNIMUX-USBV-2 USB KVM switch

2.Press and hold the CPU SELECT button on the switch

3.Re-connect power to the switch

4.Release the CPU SELECT button

6

Image 8
Contents Fax330-562-1999 Danner Dr Tel330-562-7070Aurora, OH Warranty Information Introduction MaterialsTypes of User Input Devices Supported Types of CPUs SupportedFeatures and Functions Installation UnimuxNrti Using the NTI Switch CPU SelectKeyboard Control PressCommand Mode Default Value ResetFunction KeystrokeScan Mode Broadcast ModeNormal Mode Mice and Trackballs with MACsKeyboard Features Power Key Emulation Win95 Keyboards Mac CPU Sun CPUTranslation Capabilities Translation TablesInternational Sun Keyboards MACKeyboardCountry Codes Technical Specifications TroubleshootingUSB Type B USB Type a VGA VideoModel no UNIMUX-USBV-2 Serial no Date Inspected by