METRObility Optical Systems R104-11 manual Duplex Switch FD

Page 7

Duplex Switch (FD)

Switch FD determines the duplex mode on all ports that have auto- negotiation disabled.

The ports will operate at full duplex if FD is OPEN. (default)

They will operate at half duplex if FD is CLOSED.

If auto-negotiation is enabled on a port, that port will ignore the FD switch setting.

For example, if FD is enabled and auto-negotiation is disabled on Ports 1 and 2 and enabled on Ports 3 and 4, then Ports 1 and 2 will operate at full duplex, while Ports 3 and 4 will ignore the FD switch setting. The duplex mode for Ports 3 and 4 will be determined through the auto- negotiation process.

Half-Duplex Flow Control Switch (HDFL)

For ports operating at half duplex, the R104 provides an option to enable half-duplex flow control (backpressure). When half-duplex flow control is activated, the Radiance card generates a jamming pattern to force a collision on a port if a buffer cannot be allocated for the port’s incoming packets. Half-duplex flow control is enabled by default (OPEN).

The HDFL switch must be CLOSED to disable half-duplex flow control on all four ports. The switch must be OPEN to enable HDFL on all ports.

Metrobility 4- port Switch 7

Image 7
Contents Installation & User Guide Metrobility Four-port Switch Table of Contents Overview¨ 1Unpack the Line Card 2Set the SwitchesAuto-Negotiation Switch AN1, AN2, AN3, AN4 Duplex Switch FD AN1 3Install the Card 4Connect to the Network Full-Duplex Flow Control Fdfl LED IndicatorsNetwork Connections Technical SpecificationsCSA Product Safety, EMC and Compliance StatementsWarranty and Servicing Metrobility 4-port Switch 5660-000023 D 12/06