Paradyne 3172, 3174 manual User Configuration Options 2 Factory Comments/Description, None, 19.2

Page 14

Table 7. User Configuration Options (2 of 2)

Option

Factory

Comments/Description

 

 

 

Com Rate:

1.2

Selects the bit rate for the COM port.

(Communication Port

 

 

2.4

 

Rate)

 

 

 

 

 

4.8

 

 

 

 

 

9.6

 

 

 

 

 

14.4

 

 

 

 

 

19.2

 

 

 

 

 

38.4

 

 

 

 

Char Length:

7

Selects the character length for the COM port.

 

 

 

 

8

 

 

 

 

CParity:

None

Selects the parity for the COM port.

(Communication Port

 

 

Even

 

Parity)

 

 

 

 

 

Odd

 

 

 

 

CStop Bits:

1

Selects the number of stop bits for the COM

(Communication Port

 

port.

1.5

Stop Bits)

 

 

 

 

 

2

 

 

 

 

Ignore DTR:

Yes

Specifies whether the COM port ignores DTR.

 

 

 

 

No

 

 

 

 

Aux Use:

None

Controls how the auxiliary port is used.

 

 

 

 

SNMP

 

 

 

 

 

Daisy

 

 

 

 

Aux Rate:

9.6

Configures the bit rate for the auxiliary port.

 

 

 

 

14.4

 

 

 

 

 

19.2

 

 

 

 

 

38.4

 

 

 

 

12

Image 14
Contents E1 DSU/CSU Document Feedback Acculink 3172 and 3174 E1 DSU/CSU Product Documentation OnlineQuick Start Procedure Ferrite ChokeBe set to open when using the 120-ohm interface Cabling ExamplesConfiguration Options LEDPort Configuration Options 1 Factory Comments/Description HDB3Halt Port Configuration Options 2 Factory Comments/DescriptionBoth IntPort Configuration Options 3 Factory Comments/Description ClearUnassigned Line Line 1 Displays Meaning Comments/DescriptionRsvd 384 NETBlock Line Line 1 Displays Comments/Description 2048 General Configuration Options Factory Comments/DescriptionUser Configuration Options 1 Factory Comments/Description Ascii19.2 User Configuration Options 2 Factory Comments/DescriptionNone Alarm Configuration Options Factory Comments/Description ReadPPP SlipSnmp Trap Configuration Options Factory Comments/Description AllImportant Safety Instructions EMI Notices United States EMI NoticeCE Marking Directives