Paradyne manual Acculink 3165 DSU/CSU

Page 3

TM

ACCULINK 3165 DSU/CSU

Quick Reference

Document Number 3165-A2-GL11-30

January 1998

Quick Start Procedure

The following procedure is for experienced DSU/CSU users who are familiar with the 3165 DSU/CSU installation process and have no special requirements for their application. See the ACCULINK 316x Data Service Unit/Channel Service Unit Operator's Guide (Document No. 3160-A2-GB21) for more information.

1.Attach the power cord to the rear of the DSU/CSU and the other end to a grounded 115 Vac power outlet.

2.Attach the 3165 DSU/CSU network connection to the T1 network using the appropriate cable. Attach the 3165 DSU/CSU to the customer premises equipment via the port connector.

3.Power on the DSU/CSU to perform the power-up self-test.

4.If you intend to use front panel emulation, connect the cable from the PC to the COM port on the rear panel of the DSU/CSU.

5.If you intend to manage the 3165 DSU/CSU with SNMP, cable either the COM or MODEM port (as appropriate for your configuration). Then, configure the SNMP management link.

6.The Factory 1 configuration for ESF framing format and B8ZS line coding format is the default configuration and is appropriate for most networks. If this configuration does not work for you, try the Factory 2 configuration for D4 framing format and AMI line coding format. To further customize configuration options, refer to Changing Configuration Options in Chapter 3, Operation, and to Appendix C, Configuration Options, in the ACCULINK 316x Data Service Unit/Channel Service Unit Operator's Guide.

7.During the power-up self-test, the FAIL LED flashes, then all LEDs blink twice. When the test is complete, verify that the DSU/CSU is functional by observing that the OK and NETWORK SIG LEDs are lit.

1

Image 3
Contents Acculink 3165 DSU/CSU Copyright  1998 Paradyne Corporation All rights reserved Acculink 3165 DSU/CSU Cabling Examples PstnConfiguration Options Port Configuration Options 1 AMI Port Configuration Options 2Network Interface Configuration Options ESFChannel Configuration Options 1 N1 N2 N3 ...... N24 Channel Configuration Options 2If external General Configuration OptionsNET 1544Ascii User Configuration Options 1User Configuration Options 2 User Configuration Options 3 Specifies whether a password isMinutes that causes a Alarm Configuration Options Management ± General Configuration Options 1 Specifies the default network Management ± General Configuration Options 2To access the device when Subnet Mask needed to accessAll Management ± Trap Configuration OptionsTrap manager. This configuration For Trap Manager n