Paradyne 7511 technical manual Troubleshooting, Symptom Possible Cause Recommendations

Page 12

Troubleshooting

If the 7511 Dual DSU does not turn on the OK LED after its power-up self-test, refer to the following table.

Symptom

Possible Cause

Recommendations

 

 

 

No power, or LEDs

H The power supply to the

If other devices in the carrier are

are not solidly lit.

carrier has failed.

functioning, ensure that the card is

 

H The card is not seated

completely seated in the rear

 

connector plate and that the

 

properly.

 

connector plate is tightly fastened to

 

 

 

 

the carrier backplane.

 

 

 

Power-up self-test

The DSU has detected an

H Reset the card by pulling it

fails. Only the Alarm

internal hardware failure.

slightly out of the carrier then

LEDs are on after

 

replacing it.

power-up.

 

H Contact your service

 

 

 

 

representative.

 

 

 

An Alarm LED is on.

DDS Mode:

H Verify the subscriber loop rate.

H The subscriber loop

H If the NS LED is lit:

rate is not matched to

± Verify that the DSU is

the 7511's configured

connected to the network

rate.

± Request a CSU loopback from

H No DDS Signal

your network service provider

 

 

 

LADS mode:

Configure both units to the same

H The 7511 configured rate

rate.

 

does not match its

 

partner's rate.

 

 

 

Crossed pair connection.

Check interface connections and

(LADS mode only: If the RX

cable.

leads are connected to

 

each other, the NS LED

 

also will be on.)

 

 

 

One of several other alarm

H If the OOS LED is lit:

conditions exists:

± Check the status of the remote

 

H Out of Service

DSU

± Initiate a Remote Loopback

H Out of Frame

 

H Bit errors detected

H Try a different DSU with the

during loopback test

same network connection. If the

(which also causes an

problem persists, contact your

Out of Frame condition)

service representative.

 

 

12

January 1999

7511-A2-GN10-10

Image 12
Contents Package Checklist Product Documentation on the World Wide WebPreparation Installing the Dual DSU Cables You May Need to OrderLine Rate Off KbpsConfiguration Options 2 Switch Options and Usage Configuration Options 3 Switch Options and Usage Configuration Options 4 Switch Options and Usage Off Off StandardOff Constant Off StandardConfiguration Options 5 Switch Options and Usage Installing the Rear Connector Plate Installing the DSU Card Circuit Pack Lock495-14797 Installing the Network and DTE Cables Troubleshooting Symptom Possible Cause RecommendationsImportant Safety Instructions January Government Requirements DDS Facility Interface Code Data RateWarranty, Sales, and Service Information Copyright E 1999 Paradyne Corporation