Paradyne 3151 CSU manual 495-14797

Page 5

5.Insert the CSU circuit card into the appropriate slot in the carrier. The power-up self-test begins.

495-14797

6.If you intend to use front panel emulation, connect the cable from the PC to Port 2 on the Auxiliary Backplane using the COM port adapter and COM-port-to-PC cable.

7.The Factory 1 configuration for ESF framing format and B8ZS line coding format is the default configuration and is appropriate for most networks. If this configuration does not work for you, try the Factory 2 configuration for D4 framing format and AMI line coding format. To further customize configuration options, refer to Changing Configuration Options in Chapter 3, Operation, and Appendix C, Configuration Options, in the ACCULINK 315x Channel Service Unit Operator's Guide.

8.During the power-up self-test, the FAIL LED flashes, then all LEDs blink twice. When the test is complete, verify that the CSU is functional by observing that the OK, NETWORK SIG, and DTE SIG LEDs are lit.

3

Image 5
Contents Acculink 3151 CSU Copyright  1998 Paradyne Corporation All rights reserved Acculink 3151 CSU Comsphere 495-14797 Configuration Options Network Interface Configuration Options 1 DTE Interface Configuration OptionsESF AMIGeneral Configuration Options Network Interface Configuration Options 2User Interface Configuration Options 1 AISAscii User Interface Configuration Options 2User Interface Configuration Options 3 Alarm Configuration Options User Interface Configuration Options 4General Management Configuration Options 1 PPP General Management Configuration Options 2Management Trap Configuration Options 1 Trap I/F Management Trap Configuration Options 2Both