Patton electronic 4 V.52 BER Test Generator, Patton Electronics MODEL1093 Specifications

Page 10

5.3.4 V.52 BER TEST GENERATOR

The Model 1093 has a built-in test pattern generator and detector. It can be invoked at both ends of a link simultaneously or it can be used with the Local Analog or Remote Digital Loopbacks. The follow- ing example requires two operators: one to initiate and monitor the test at the local Model 1093, and one at the remote Model 1093. To use the V.52 BER test by itself, both operators should simultaneously follow these steps.

1.Locate the 511/511E toggle switch on the front panel of the Model 1093 and move it DOWN. This activates the V.52 BER test mode and transmits a 511 pseudorandom test pattern to the other unit. If any errors are received, the receiving Model 1093’s red ER LED will blink sporadically.

NOTE: For this test to function, the 511 switch on both Model 1093’s must be on.

2.If the test indicates no errors are present, move the V.52 toggle switch UP, activating the 511/E test. The 511/E test transmits the 511 pseudorandom test pattern and injects intentional errors about once per second. If the test is work- ing properly, the receiving Model 1093’s red ER LED will blink regularly.

A successful 511/E test will confirm that the link is in place, and that the Model 1093 built-in 511 generator and detector are working properly.

3.This test can be done by one operator by first activating the local analog loop or remote digital loop.

APPENDIX A

PATTON ELECTRONICS MODEL1093

SPECIFICATIONS

Transmission Format:

Synchronous

Transmission Line:

Unconditioned twisted pair 19 - 26 AWG

Clocking:

Internal, external or receive loopback

Distance:

Up to 6 miles (19 AWG @ 256 kbps)

Data Rates:

256 and 512 kbps (switch selectable)

Carrier Control:

Constantly on or Controlled by RTS

RTS/CTS Delay:

No delay, short delay (4 - 9 mSec), long

 

delay (33 - 71 mSec).

Diagnostics:

V.52 compliant bit error rate pattern

 

(511/511E pattern) generator and detector

 

with error injection mode; V.54

 

compliant—local analog loopback and

 

remote digital loopback, activated by front

 

panel switch or via serial interface

LED Indicators:

TD, RD, RTS, CD, DTR, ER and TM

 

(test mode)

Isolation:

Minimum 3000V RMS via transformers

Surge Protection:

Immune to IEC-801-5 Level 2, 1kV

DCE/DTE Interface:

Field-replaceable Quick ConnectTM

 

modules.

Twisted Pair Interface:

8-position modular jack (RJ-45)

Power:

115/230 VAC (switch selectable), 50/60 Hz;

 

85 - 256 VAC, 50/60 Hz (universal input

 

option); 48 VDC (option). 5 watts.

Temperature Range:

0-50°C (32-122°F)

Altitude:

0-15,000 feet

Humidity:

5 to 95% non-condensing

Dimensions:

7.3” x 6.6” x 1.62”

 

(185mm x 168mm x 41mm)

Weight:

2.02 lbs. 1.0 Kg

17

18

Image 10
Contents User Manual CE Notice ServiceRadio and TV Interference TEL 301 Email support@patton.comExternal DIP Switch Settings FeaturesDescription S1 Summary Table Signal Twisted Pair Connection Using RJ-45Connection to the Twisted Pair Interface Connection to the Serial Port Signal PIN#Changing Quickconnect Modules AC Power Connection Reconfiguring the X.21 Quickconnect ModuleConnection to the Power Source Connection to a DTE DeviceLED Status Monitors POWER-UPDiagnostics Local Analog Loopback LALRemote Digital Loopback RDL Local Digital Loopback LDLPatton Electronics MODEL1093 Specifications 4 V.52 BER Test GeneratorPatton Electronics MODEL1093 Cable Recommendations Wire Gauge Capacitance ResistanceAlways use twisted pair wire-this is not an option Patton Model # DescriptionPin # Signal Patton Electronics Model Interface PIN AssignmentsFrame Ground