Patton electronic 1140ARC user manual Fiber Connections, Operation, LED Status Monitors, Power-Up

Page 8

4.3.2 FIBER CONNECTIONS

The Model 1140ARC is designed to work with the self-powered Model 1140A, or with another Model 1140ARC. In either case, you will need one unit at each end of a dual fiber cable. This cable connects to the Model 1140ARC using either ST or SMA connectors. Figure 7 (below) shows a close-up of each of these connector types.

alignment pin faces down

Figure 7. Close up of ST and SMA connections

13

5.0 OPERATION

Once you have configured each Model 1140ARC and connected the cables, you are ready to operate the units. This section describes the LED status monitors and power-up procedure.

5.1 LED STATUS MONITORS

The Model 1140ARC features ten front panel status LEDs that indicate the condition of the modem and communication link:

The green “PWR” LED glows when power is applied to the modem card through its mid-plane chassis connection.

The green “TD” and “RD” indicators blink to show positive state data activity. The Red “TD” and “RD” indicators blink to show negative state data activity. Solid red indicates an idle state.

The green “RTS” and “CD” indicators glow solid to show the control signal is on. The red “RTS” and “CD” indicators glow solid to show the control signal is off. When the 1140ARC is connected to a DTE, RTS will glow green for an incoming signal on RS-232 pin 4. CD will glow green for an incoming signal from the line, and an outgoing signal on RS-232 pin 8.

The “Test” LED glows when either the Local Analog Loopback (LAL) or Remote Digital Loopback (RDL) V.54 test mode is initiated. The “Error” LED blinks when an error is detected by the V.52 diagnostics.

5.2POWER-UP

There is no power switch on the Model 1140ARC: Power is automatically applied to the 1140ARC when its card-edge connector makes contact with the chassis’ mid-plane socket, or when the chassis’ power supply is turned on. Note: The 1140ARC is a “hot swappable” card—it will not be damaged by plugging it in or removing it while the rack is powered up.

When the local and remote units are both powered up, and are passing data normally, the following LED conditions will exist:

PWR = green

TD & RD = flashing red and green

RTS & CD = green

Test = off

Error = off

14

Image 8
Contents User Manual Warranty Information ServiceRadio and TV Interference CE NoticeFeatures ConfigurationFront Card Configuration General InformationConfiguration Switch SET S1 S1 Summary TableS2 Summary Table Configuration Switch SET S2Rear Card Configuration Installation Rack Power SupplyHOW the Jumper Works DTE Shield Pin 1 & Frgnd JB1Switching the Power Supply On and Off Installing the Model 1140ARC Into the ChassisWiring UP the Model 1140ARC 1 RS-232 ConnectionPOWER-UP Fiber ConnectionsOperation LED Status MonitorsRemote Digital Loopback RDL Test ModesLocal Analog Loopback LAL Using the V.52 BER Test Independently Appendix a Patton Model 1140ARC SpecificationsTemperature Range 0-60C32-140F Weight 2 ozPatton Model # Description Appendix B Patton Model 1140ARC Factory Replacement PartsAppendix C Patton Model 1140ARC PIN Configurations Appendix D Block Diagram