2.3 TYPICAL APPLICATION
The
Corporate Headquarters
Model
LAN
2-Wire Leased Line
Ρεμοτε/Σατελλιτε Οφφιχε
Model
LAN
Figure 1. Typical Application
3.0 INSTALLATION
The Model 2112 requires no configuration. You only need to con- nect the Ethernet interface, line interface between the units and power. This section describes these connections.
Power | IEC Power | 10BaseT | Line |
Switch | Jack | Interface | Interface |
| Figure | 2. Model 2112 Rear Panel. |
|
3.1 CONNECTING THE TWISTED PAIR LINE INTERFACE
The Model 2112 supports communication between two peer Ethernet LAN sites at a distance up to 3.6 miles (5.8 km) over 24AWG (.5mm) twisted pair wire. Follow the steps below to successfully con- nect the Model 2112 Line Interfaces.
1.These units work in pairs. One unit in the pair must be a Model
2.To function properly, the two Model 2112s must be connected together using twisted pair metallic wire. This twisted pair must be unconditioned, dry, metallic wire, between 19 (.9mm) and 26 AWG (.4mm). Standard
5 | 6 |