4.0 INSTALLATION

The sections on the next page describe installing the following:

Model 460 (see section 4.1, “Installing the Model 460” on page 8)

Model 460-TBP (see section 4.2, “Installing the Model 460-TBP” on page 8)

Refer to the appropriate section to install your unit.

4.1 INSTALLING THE MODEL 460

Do the following:

1.Refer to the pin configuration below when assembling the cable that will connect to the RJ-45 jack.

2.Plug the modular cable connector into the RJ-45 jack.

RJ-45 Pin(s)

Function

 

 

1 and 2

TX pair

3

TX shield

 

 

4 and 5

RX pair

 

 

6

RX shield

 

 

3.Connect the coaxial cables to the TX Out and RX In connectors. Congratulations, you have finished installing the Model 460!

4.2INSTALLING THE MODEL 460-TBP

Do the following:

1.Strip the outer jacket insulation from the twisted pairs about 1 inch.

2.Strip back the insulation on each of the wires about 0.25 inches.

8

Image 8
Contents User Manual Contents Warranty Information Service and Support CE NoticeProduct Description Terminal Block RJ-45 Jack and Terminal Block DescriptionsShielded RJ-45 Jack Configuration RJ-45 120 ohm Jumper Coax BNC 75 ohm Pin 3 TX ShieldTX Out Shield Pin 6 RX ShieldJP1 and JP2 locations for 460M Installation Installing the ModelRJ-45 Pins Function Installing the Model 460-TBPCoax CPETwisted-pair Power Supply Operating TemperatureDimensions Appendix a