PATTON ELECTRONICS CO.
137001UA
JP4 and JP5 to IN
Provided Pin 9 and 10 Test Voltage
JP6 to OUT
CTS delay = No Delay
JP1, JP2 and JP3 to IN
Factory Test Jumpers must be installed
3018/V24 (CTS MSD-8C)
Switch 9 - positions 4 and 6 to OFF, 1, 2, 3 and 5 to ON
Switching Mode = Priority
Signal Ground not connected to Chassis Ground
JP4 and JP5 to IN
Provided Pin 9 and 10 Test Voltage
JP6 to OUT
CTS delay = No Delay
JP1, JP2 and JP3 to IN
Factory Test Jumpers must be installed
If the system application requires one or more of the default settings to be changed, it will be necessary to remove the top cover of the enclosure to access and change the DIP switches located on the printed circuit board.
Disassembly
Remove the top cover by unscrewing the phillips head screws located on the left and right sides of the unit. The configuration switches and jumpers are located on the PCB as indicated on the appropriate strapping guide in the Appendix of this manual. After the switch selection activity is completed, REINSTALL THE TOP COVER BEFORE
CONNECTING TO AN AC POWER SOURCE.
Setup & Installation |