Patton electronic RS-232 Switch SET SW1, SW1 Summary Table, Switch SET SW2, SW2 Summary Table

Page 4

SWITCH SET SW1

The configuration switches on switch set SW1 set analog loopback, digital loopback and V.54 enable/disable. The default settings are summarized in Figure 3 (below).

SW1 SUMMARY TABLE

Position

Function

Factory Default

SW1-1

DTE Control of Analog Loopback

On

Enabled

 

 

 

 

SW1-2

DTE Control of Digital Loopback

On

Enabled

 

 

 

 

SW1-3

Not Used

Off

n/a

SW1-4

Not Used

Off

n/a

 

 

 

 

SW1-5

Not Used

Off

n/a

 

 

 

 

SW1-6

Not Used

Off

n/a

 

 

 

 

SW1-7

Not Used

Off

n/a

 

 

 

 

SW1-8

V.54 Enable/Disable

Off

Enabled

 

 

 

 

Figure 3. Summary of DIP switch settings for set SW1

SW1-1: DTE Initiation of Local Analog Loopback Test

The setting for switch SW1-1 determines whether or not the Model 1035’s local analog loopback test can be initiated by raising pin 18 on the DTE.

SW1-1

Setting

On

Pin 18 initiation enabled

Off

Pin 18 initiation disabled

SW1-2: DTE Initiation of Remote Digital Loopback Test

The setting for switch SW1-2 determines whether or not the Model 1035’s remote digital test can be initiated by raising pin 21 on the DTE.

SW1-2

Setting

On

Pin 21 initiation enabled

Off

Pin 21 initiation disabled

SW1-3 through SW1-7: Not Used

(continued)

5

SW1-8: V.54 Enable/Disable

The setting for switch SW1-8 determines whether or not the Model 1035’s V.54 circuits are enabled.

SW1-8

Setting

On

V.54 test functions disabled

Off

V.54 test functions enabled

SWITCH SET SW2

The configuration switches on switch set SW2 set data rate, clock source, carrier control and RTS/CTS delay. The default settings are summarized in Figure 4.

SW2 SUMMARY TABLE

Position

Function

Factory Default

SW2-1

Data Rate

Off

}

 

SW2-2

Data Rate

On

56 Kbps

SW2-3

Data Rate

Off

 

SW2-4

Clock Source

On

}

Internal

SW2-5

Clock Source

On

 

 

 

 

 

 

SW2-6

Carrier Control

Off

 

Constantly On

 

 

 

 

 

SW2-7

RTS/CTS Delay

On

}

7 ms

SW2-8

RTS/CTS Delay

On

 

 

 

 

 

 

Figure 4. Summary of DIP switch settings for set SW2

SW2-1 through SW2-3: Data Rate Setting

Switches SW2-1 through SW2-3 are set in combination to determine the synchronous data rate for the Model 1035.

SW2-1

SW2-2

SW2-3

Setting

On

Off

Off

64 Kbps

Off

On

Off

56 Kbps

Off

Off

On

32 Kbps

 

 

(continued)

 

 

 

6

 

Image 4
Contents User Manual Service FeaturesRadio and TV Interference DescriptionSwitch Settings Configuration SwitchesOpening the Case Switch SET SW1 Switch SET SW2SW1 Summary Table SW2 Summary TableSignal Twisted Pair Connection Using RJ-11 or RJ-45Connection to the Twisted Pair Interface Signal PIN# Color ‡ Connection to the RS-232 and V InterfacesConnection to a DTE Device Connection to AN RS-232 DCE DeviceFront Panel Switches LED Status MonitorsTest Modes Local Analog Loopback LALPOWER-DOWN Patton Model 1035 SpecificationsPIN Configurations Block Diagram Direction RS-232 PIN-OUT Reference DB-25