Patton electronic 1012B user manual EIA RS-232, ITU/CCITT

Page 7

 

 

APPENDIX A

 

 

 

 

SPECIFICATIONS

 

 

Transmission Format:

Asynchronous, full duplex, half duplex

Transmission Line:

Two unconditioned twisted pair AWG 19–26

Interfaces:

EIA RS-232, ITU/CCITT V.24

Data Rates:

0–38.4 kbps

 

 

Isolation:

Minimum 1500 V RMS via custom

 

 

transformers

 

 

Surge Protection:

600W power dissipation at 1 mS

Factory Switch Setting:

DCE (transmits from RS-232 on pin 3)

Control Signals:

CTS follows RTS from the terminal (DTE);

 

 

DSR follows DTR from the terminal (DTE);

 

 

CD indicates reception of carrier

RTS/CTS Delay:

Approximately 30 mS

Connectors:

DB-25 male or female on RS-232 side; RJ-

 

 

11, RJ-45 or terminal block with strain relief

 

 

on line side

 

 

Power Supply:

No external power required; uses power

 

 

from EIA data and control signals

Temperature Range:

0–60°C (32–140°F)

 

 

Altitude:

0–15,000 feet (0–4,500 meters)

Humidity:

5 to 95% non-condensing

Weight:

2 oz. (60 grams)

 

 

Dimensions:

3.54L x 2.09W x 0.79H in.

 

 

(90L x 53W x 20H mm)

 

 

 

 

 

 

 

 

Distance Table (miles)

 

 

 

 

 

 

 

 

 

 

 

 

Data

 

 

Wire Gauge

 

 

 

Rate

 

 

 

 

 

 

 

 

 

19

 

24

 

26

 

 

1,200 to 38,400

6.0

 

4.0

 

2.5

 

APPENDIX B

RS-232C PIN CONFIGURATIONS

DIRECTION

"DCE" STANDARD SETTING

DIRECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

- (FG) Frame Ground

 

 

 

 

 

 

 

 

 

2

- (TD) Transmit Data

To Model 1012B

 

 

 

 

 

 

 

3

- (RD) Receive Data

From Model 1012B

 

 

 

 

 

 

 

4

- (RTS) Request to Send

To Model 1012B

 

 

 

 

 

 

 

5

- (CTS) Clear to Send

From Model 1012B

 

 

 

 

 

 

 

6

- (DSR) Data Set Ready

From Model 1012B

 

 

 

To Model 1012B

Data Term. Ready (DTR) - 20

 

 

7

- (SG) Signal Ground

 

 

 

 

 

8

- (CD) Carrier Detect

From Model 1012B

 

 

 

 

 

 

 

 

9

- External Power

To Model 1012B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIRECTION

"DTE" STANDARD SETTING

DIRECTION

 

 

 

 

 

 

 

 

1- (FG) Frame Ground

 

 

 

 

 

 

 

 

2- (TD) Transmit Data

From Model 1012B

 

 

 

3- (RD) Receive Data

To Model 1012B

 

 

 

4- (RTS) Request to Send

From Model 1012B

 

 

 

5- (CTS) Clear to Send

To Model 1012B

 

 

 

6- (DSR) Data Set Ready

To Model 1012B

From Model 1012B

Data Term. Ready (DTR) - 20

 

7- (SG) Signal Ground

 

 

8- (CD) Carrier Detect

To Model 1012B

 

 

 

 

 

 

9- External Power

To Model 1012B

 

 

 

 

 

 

 

 

 

 

11

12

Image 7
Contents Copyright Patton Electronics Company All rights reserved User ManualDescription ServiceFeatures Radio and TV InterferenceConfiguration Setting the Model 1012B AS DCE or DTEDCE DTE Terminal Block Twisted Pair Connection Setting the RTS/CD Carrier Control JumperHOW to Connect to the Twisted Pair Interface InstallationModular Twisted Pair Connection Signal/Pin AssignmentsSignal Signal PIN#Optional Connection Dual Modular Jacks EIA RS-232, ITU/CCITT Appendix C Model 1012B Block Diagram