3.2 SWITCH SETTINGS

All possible settings for the Model 1025’s configuration switches are presented in the summary table and descriptions below. If you have additional questions regarding configuration, contact Patton Technical Support at (301) 975-1007.

SWITCH SUMMARY TABLE

 

Position

Function

Factory Default

 

Switch 1

Transmit Clock

Off

}

Internal

 

Switch 2

Transmit Clock

On

Clock

 

 

 

 

 

 

 

Switch 3

RTS/CTS delay

On

 

7 mSec delay

 

 

 

 

 

 

 

Switch 4

Data Rate

On

}

 

 

Switch 5

Data Rate

Off

9,600 bps

 

Switch 6

Data Rate

Off

 

Switches 1 and 2: Transmit Clock

Switches 1 and 2 are used together to specify the clocking method. The Model 1025 can provide an internal clock (Pin 15), receive an external clock (from Pin 24), or loopback a received clock.

Switch 1

Switch 2

Setting

On

On

External Clock

On

Off

External Clock

Off

On

Internal Clock (Default)

Off

Off

Receive Loopback

Switch 3: RTS/CTS Delay

After request to send (RTS) is raised by the host terminal, the

Model 1025 raises CTS after a delay in order to give the remote termi- nal time to receive an incoming signal. Depending on the type of envi- ronment, either a 7mS or 53mS delay can be selected.

Switch 3

Setting

On

7 mS (Default)

Off

53 mS

Switches 4, 5 and 6: Data Rate

Switches 4 thru 6 are set in combination to allow the Model 1025 to be used at data rates from 1.2 to 19.2 Kbps.

Switch 4

Switch 5

Switch 6

Setting

On

On

On

1.2

Kbps

On

On

Off

2.4

Kbps

On

Off

On

4.8

Kbps

Off

On

On

7.2

Kbps

On

Off

Off

9.6

Kbps (Default)

Off

On

Off

14.4

Kbps

Off

Off

On

19.2

Kbps

Off

Off

Off

19.2

Kbps

5

6

Image 4
Contents Model 1025 and 1025S Service Radio and TV InterferenceCE Notice Telephone 301 Email support@patton.comSwitch Locations FeaturesDescription Switch Settings Switch Summary TableSwitches 1 and 2 Transmit Clock Switch 3 RTS/CTS DelayTwisted Pair Connection Using RJ-11 or RJ-45 SignalSignal PIN# Color Twisted Pair Connection Using Terminal BlocksXMT RCV Connection to the RS-232 Interface Connection to a DTE DeviceSpecifications Temperature Range 0-60C32-140FWeight 2 oz Connection to a DCE DeviceRS-232 PIN Configurations Direction DCE Standard Setting