Patton electronic user manual Installation of Model 570/580 Surge Protectors

Page 4

2.Install the Model 570/580 between the incoming UTP line and the protected equipment (see Figure 3, below). This installation requires a straight through Cat-5 patch cable with modular RJ-45 connectors (supplied with unit). Note: It doesn’t matter which end of the Model 570/580 plugs into which cable.

Cat-5 patch cable to

Cat-5 input

protected equipment

from network

(6 inches or less)

 

Connection to

chassis ground

Figure 3. Installation of Model 570/580 Surge Protectors.

3.Locate a metal chassis ground on the equipment to be protected. This is often a hex screw on a D-shell or AUI connector. Sometimes a metal back panel is attached by screws, one of which can be used for chassis grounding. If you cannot locate a chassis ground connection on your equipment, contact Patton Technical Support at (301) 975-1000 to discuss an alternative grounding solution.

4.Connect the braided ground strap directly to the chassis ground connection you have located (see Figure 3, above). The best way to make this connection is to attach the braided metal strap using a hex nut or screw on your device.

Caution: Surge energy may run both directions on the ground strap. To provide the best protection, it is essential that the ground strap on the Model 570/580 be connected to the chassis ground of the protected device. Do not lengthen the ground strap of the Model 570/580 or connect to a ground other than chassis ground unless instructed to do so by Patton Technical Support.

Connection of the Model 580 at a Barrier (Wall, Bldg Entrance, etc.)

1.Disconnect the UTP cable from the wall jack or patch panel jack.

2.Install the Model 580 between the UTP line and the jack. This installation requires a straight through Cat-5 patch cable with modular RJ-45 connectors (supplied with unit). Note: It doesn’t matter which end of the Model 580 plugs into which cable.

3.Locate an electrical ground nearest the jack. Often this will be on an electrical panel or sub panel. If you cannot locate a nearby electrical ground, contact Patton Technical Support at

(301) 975-1000 to discuss an alternative grounding solution.

4.Connect the braided ground strap directly to the electrical ground you have located. The best way to make this connection is to attach the braided metal strap to a metal panel or wallplate screw using a hex nut or screw.

Caution: Surge energy may run both directions on the ground strap. To provide the best protection, it is essential that the ground strap on the Model 580 be connected to an electrical ground.

5

6

Image 4
Contents User Manual Warranty Information ServiceFeatures General InformationInstallation Installation ProceduresProduct Applications POINT-OF-USE Application ModelInstallation of Model 570/580 Surge Protectors Appendix a Specifications Connectors RJ-45 FemaleCharacteristic Impedance 100 Ohms Meets IEC standards 801.2, 801.4 and 801.5 CE MarkAppendix B EIA/TIA TSB-40A Compliance Appendix BFigure C-5.Return Loss measurements for Patton Model