Patton electronic MODEL 2126 user manual Specifications, Interface Connections

Page 16

APPENDIX A

SPECIFICATIONS

Operating Systems Supported: Novell 2.15, 2.2, 3.11, 3.12

 

and 4.00

Utilities Supported:

LPR, FTP, TELNET and PING

APPENDIX B

INTERFACE CONNECTIONS

Model 2127 Centronics Interface

Network Connection:

10Base2

Protocols:

IPX/SPX, TCP/IP

Frame Types:

802.3, Ethernet II, 802.2 and

 

Ethernet SNAP

Parallel Ports:

one

Parallel Speed:

60,000 bytes /sec (printing on

 

a Novell 3.11 network )

Connectors:

Centronics male (Parallel)

 

BNC-type female (10Base2)

Cable Recommendations:

Ethernet, coaxial cable

 

conforming to 10Base2

 

standards

Power Supply:

External, wall mount

 

(120V AC domestic, 220V AC

 

international)

Temperature Range:

2-60°C (37-140°F)

Altitude:

0-10,100 feet

Humidity:

Up to 95% non-condensing

Dimensions:

4.0” x 2.1” x 0.8”

Weight:

3 oz. (max)

Ground -19

Ground -20

Ground -21

Ground -22

Ground -23

Ground -24

Ground -25

Ground -26

Ground -27

Ground -28

Ground -29

Ground -30

-31

Error -32

Ground -33

-34

-35

Ground -36

1- Strobe (Output)

2- Data bit 0 (I/O)

3- Data bit 1 (I/O)

4- Data bit 2 (I/O)

5- Data bit 3 (I/O)

6- Data bit 4 (I/O)

7- Data bit 5 (I/O)

8- Data bit 6 (I/O)

9- Data bit 7 (I/O)

10- Acknowledge (Input - active low)

11- Busy (Input - active high)

12- Paper End

13- Select

14-

15- No Connect

16-

17-

18- +5 volts

29

30

Image 16
Contents Model Warranty Information InstallationGeneral Information Novell OperationChecking The Supplied Parts FeaturesPhysical Connection and Operation Installing Uconnect on a Workstation What if a status page does not print after 15 30 seconds?Using Pconsole Uconnect Commands Locating the Print Server on the NetworkServer Name Configuration within Novell using Uconnect General ConfigurationNovell Configuration Advanced Novell Configuration4 TCP/IP Configuration Personal Netware ConfigurationTesting within Novell using Uconnect Reset to Factory DefaultsExit Troubleshooting within Novell Printing within NovellNprint testfile.doc PS=PESERV Queue=TEST Upgrading within NovellNovell Specific Locating the Print Server on the TCP/IP NetworkAssigning the Internet Address Arp -S ether IPaddress NICaddress whereGeneral NovellTcpip PersonalSET PU = no PUT IMAGE.BIN Specifications Interface Connections