Patton electronic 2603, 2620 quick start Connect to the local IP network, Modifying the IP address

Page 4

2.2 Modifying the IP address

1.Display current IP interface settings for the IPLink Ethernet LAN port.

ip list interfaces <enter>

IP

Interfaces:

 

 

ID

Name IP Address

DHCP

Transport

---

----------------------

----------

--------------

1 ip1 192.168.200.10 disabled <eth1>

----------------------------------------------------

2.Modify the IP address for the LAN port according to your network requirements.

ip set interface ip1 ipaddress 10.10.10.5 255.255.255.0

Note The above IP address (10.10.10.5/24) is only an example. You must choose an IP address on the same subnet as your PC.

3.Verify the new address is correct and save it in system boot memory.

ip list interfaces <enter>

system config save <enter>

Now you can connect the IPLink to your local IP network and complete the remaining configuration from your PC using a standard web browser.

3.0 Connect to the local IP network

Connect the IPLink’s (green) Ethernet port to the same Ethernet segment as your PC (see figure 2).

Note The Model 2620 does not have an MDI-X switch, so you must use a cable wired straight-through to con- nect the Model 2620’s Ethernet port to the IP network.

If you have a Model 2603, press the MDI-X switch until the Ethernet Link LED turns on.

PC

Connect to Ethernet port

Power

10/100

 

 

Crossover

 

Ethernet

 

MDI-X

 

 

Ethernet port

RX

TX

WAN

MDI-X switch

Figure 2. Connecting the IPLink to the local IP network (Model 2603/K shown)

4

IPLink 2603 & 2620 Quick Start Guide

Image 4
Contents WAN Access Router Models with internal AC power supply Power up the routerModels with external AC adaptor Models with internal DC power supply Power-up indicationConnecting a PC and logging Configure the IP addressConnect to the local IP network Modifying the IP addressLog onto the web management interface Connect the WAN portConnecting to the RJ-48C WAN port Complete the installation Customer and Technical SupportFax +1 253 663-5693 USA or +41 031 985 25 26 Switzerland Compliance Information Radio and TV Interference FCC PartEC Declaration of Conformity Product Description IPLink 2603Warranty, Trademark, & Compliance Information Industry Canada NoticeCopyright statement Trademarks statement
Related manuals
Manual 133 pages 54.65 Kb