Patton electronic quick start Grounding the EHA3201, Connecting the Twisted-Pair Line Interface

Page 4

1.1 Grounding the EHA3201

Before installing the EnviroNET G.SHDSL Router, it is important to establish a good grounding connection first.

1.Assemble a ground wire using #10 AWG wire with green-and-yellow-colored insulation and two ring ter- minals. Make the wire long enough to reach one of the following earth ground sources:

The building ground rod (generally located at the site’s main service entrance)

A sprinkler system pipe

A cold-water pipe

Building structural steel

2.Install the grounding wire between the grounding stud (see Figure 1 on page 3) and the grounding source.

1.2 Connecting the Twisted-Pair Line Interface

To function properly, the G.SHDSL Router must be connected using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.

The G.SHDSL Router is equipped with an RJ-45 interface jack (Line), which is a two-wire interface. Observe the signal/pin relationships on the G.SHDSL Router’s Line interface jack. The signal/pin relationship is shown in figure 2.

 

1 (no connection)

1

2 (no connection)

23 (no connection)

4

4

(2-Wire RING)

 

 

5

5

(2-Wire TIP)

6

6 (no connection)

7

7 (no connection)

8

8 (no connection)

Figure 2. EnviroNET G.SHDSL Router (RJ-45) twisted pair line interface.

1.3 Connecting the 10/100Base-T Ethernet Interface

The G.SHDSL Router has an unshielded RJ-45 auto-MDIX10/100Base-T interface. This port is designed to con- nect directly to a 10/100Base-T network. figure 3 shows the signal/pin relationships on this interface. You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long.

4

EHA3201 Quick Start Guide

Image 4
Contents EnviroNET G.SHDSL Router Cord is connected Installing the EHA3201 EHA3201 Bottom PanelConnecting the 10/100Base-T Ethernet Interface Connecting the Twisted-Pair Line InterfaceGrounding the EHA3201 Connecting Power EnviroNET G.SHDSL Router 10/100Base-T RJ-45 Connector PinoutConfiguring the EHA3201 Connect to a PCAdditional Information Configuring applicationsCustomer and Technical Support EHA Case Specifications Compliance Compliance InformationFCC Part 68 Acta Statement Industry Canada Notice Radio and TV Interference FCC PartEC Declaration of Conformity Authorized European RepresentativeWarranty, Trademark, & Compliance Information Buccaneer 400 Series Environmentally Sealed Connectors Cable ConnectorsEHA3201 Quick Start Guide EHA3201 Quick Start Guide EHA3201 Quick Start Guide