Polycom RMX 4000 manual Συμμορφωνεται Προσ ΤΙΣ Ουσιωδεισ Απαιτησεισ ΚΑΙ ΤΙΣ

Page 5

Deutsch [German]:

Hiermit erklärt Polycom (UK) Ltd, dass sich das Gerät RMX 4000 in

 

Übereinstimmung mit den grundlegenden Anforderungen und den übrigen

 

einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet.

Eesti [Estonian]:

Käesolevaga kinnitab Polycom (UK) Ltd seadme RMX 4000 vastavust

 

direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele

 

asjakohastele sätetele.

English:

Hereby, Polycom (UK) Ltd. Declares that this RMX 4000 is in compliance with

 

the essential requirements and other relevant provisions of Directive 1999/5/EC.

Español [Spanish]:

Por medio de la presente Polycom (UK) Ltd declara que el RMX 4000 cumple

 

con los requisitos esenciales y cualesquiera otras disposiciones aplicables o

 

exigibles de la Directiva 1999/5/CE.

Ελληνική [Greek]:

ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Polycom (UK) Ltd ΔΗΛΩΝΕΙ ΟΤΙ RMX 4000

 

ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ

 

ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ.

Français [French]:

Par la présente Polycom (UK) Ltd déclare que l’appareil RMX 4000 est

 

conforme aux exigences essentielles et aux autres dispositions pertinentes de la

 

directive 1999/5/CE.

Italiano [Italian]:

Con la presente Polycom (UK) Ltd dichiara che questo RMX 4000 è conforme

 

ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva

 

1999/5/CE.

Íslenska (Icelandic):

Hér með lýsir Polycom (UK) Ltd yfir því að RMX 4000 er í samræmi við

 

grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC

Latviski [Latvian]:

Ar šo Polycom (UK) Ltd deklarē, ka RMX 4000 atbilst Direktīvas 1999/5/EK

 

būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.

Lietuvių [Lithuanian]:

Šiuo Polycom (UK) Ltd deklaruoja, kad šis RMX 4000 atitinka esminius

 

reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas.

Nederlands [Dutch]:

Hierbij verklaart Polycom (UK) Ltd dat het toestel RMX 4000 in

 

overeenstemming is met de essentiële eisen en de andere relevante bepalingen

 

van richtlijn 1999/5/EG.

Malti [Maltese]:

Hawnhekk, Polycom (UK) Ltd, jiddikjara li dan RMX 4000 jikkonforma mal-

 

ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva

 

1999/5/EC.

Magyar [Hungarian]:

Alulírott, Polycom (UK) Ltd nyilatkozom, hogy a RMX 4000 megfelel a

 

vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb

 

elõírásainak.

Norsk [Norwegian]:

Polycom (UK) Ltd erklærer herved at utstyret RMX 4000 er i samsvar med de

 

grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.

Polski [Polish]:

Niniejszym Polycom (UK) Ltd oświadcza, że RMX 4000 jest zgodne z

 

zasadniczymi wymaganiami oraz innymi stosownymi postanowieniami

 

Dyrektywy 1999/5/WE

Português [Portuguese]:

Polycom (UK) Ltd declara que este RMX 4000 está conforme com os requisitos

 

essenciais e outras disposições da Directiva 1999/5/CE.

Slovensko [Slovenian]:

Polycom (UK) Ltd izjavlja, da je ta RMX 4000 v skladu z bistvenimi zahtevami

 

in ostalimi relevantnimi določili direktive 1999/5/ES.

Image 5
Contents Polycom RMX 4000 Hardware Guide Patent Pending Regulatory Notices United States Safety Construction DetailsCE Mark R&RTTE Directive Συμμορφωνεται Προσ ΤΙΣ Ουσιωδεισ Απαιτησεισ ΚΑΙ ΤΙΣ Chinese Communication Certificate Table of Contents Component Replacement Hardware Description Power Consumption Power SupplyPhysical IP ProtocolsSystem Functions Capacity System CapacitiesFollowing table summarizes the different system capacities HD720p HD1080p @30fps @60fps MPM+ MPM+ Resource CapacitiesCard Resources Type Voice CIF Resource Type Maximum Capacity 4 MPM+ CardsSite Safety Requirements Safety RequirementsRack Mount Safety Precautions General Installation PrecautionsUnpacking the RMX Installing the RMXPolycom RMX 4000 Hardware Guide Rack Mount Preparations Installing the RMX in a Rack or as a StandaloneStandalone RMX 4000 Installation Placing the RMX 4000 in a 19 Rack 2Installing chassis runners and RMX in a rack3RMX 4000 Rack Mount 4Removing and attaching 19 and 23 brackets Placing the RMX 4000 in a 23 RackTo reverse mount the RMX 4000 on a 19 rack Reverse Mounting the RMX 4000 in a RackConnecting the RMX 4000 to Power Sources Make sure that the power button is switched OFF on the RMX Connecting the RMX 4000 to AC PowerConnecting the RMX 4000 to -48DC Selv Power Hardware Description To connect the cables AC and DC systems RTM-IP Connecting Cables on the RMXRTM LAN on First-time Power-upFor more information about specific card connections, see RMX 4000 Front Panel RMX 4000 Components8shows the front panel of an RMX 4000 DC system Component Description 9RMX 4000 AC Rear View RMX 4000 Rear Panel10RMX 4000 DC Rear View RTM-IPLAN 3 Cntl Following items appear on the RMX 4000 rear panelStandby button Toggle between CPU activation and standby RTM IsdnISDN/PSTN Clock Source AC Power Entry Module PEMSlot ID/No Card/Component Requirement DC Power Rail ModuleComponent Slot Allocation RTM ISDN/RTM Following items appear on the RMX 4000 front panel RMX 4000 Front Panel LEDsComponent LED Color DescriptionCard Insertion Initiated If during Card removal Initiated The cardCntl 4000 Unit RTM-IP RMX 4000 Rear Panel LEDsFollowing LEDs appear on the RTM-IP 4000 card LED Color Description NameFunction Name Following LEDs appear on the RTM LANFollowing LEDs appear on the RTM Isdn RTM IsdnComponent Replacement Component Replacement Handle Using the Modified PMC Compatible Ejector LeverReplacing the Cntl 4000 Module Replacing an AC Power Supply Module Replacing an AC Power Entry Module PEM Replacing a DC Power Rail Module PRM Component Replacement Carefully slide the Fan drawer out through the front panel Replacing the Fan DrawerInserting an Air Filter Optional in the Fan Drawer Removing the MPM+ Card from the MCU Replacing a Faulty MPM+ CardComponent Replacement Carefully slide the MPM+ card out through the front panel Installing the Replacement MPM+ CardReplacing a RTM Isdn Card Installing a New MPM+ Card in a Powered On RMXPRI Cables Replacing the RTM-IP Replacing the RTM LAN Replacing the Fabric Switch Module FSM
Related manuals
Manual 2 pages 709 b