Polycom DOC2558A manual RMX 2000 Specifications

Page 8

Chapter 1- Hardware Description

RMX 2000 Specifications

Table 1-1Polycom RMX 2000 Specifications

Physical

Height

Width

Depth

Weight

3U (13.25 cm.)

19” (48.26 cm.)

15.74” (40 cm.)

Up to 16.5 Kg.

Media Protocols

Audio

Video

G.711, G. 719, G.722, G.722.1, G.729A, G.723.1, Siren14, Siren 22.

H.261, H.263, H.264.

Network Interfaces

IP, ISDN, PSTN and LAN

H.323, SIP, PSTN, LAN and ISDN.

Power Supply

AC Input/ Range, BTU

Voltage range: 100-240 VAC, 4-8 AMP, 50/60 Hz.

Maximum BTU output: 3070 per hour.

Power Consumption

AC Maximum Power consumption

900 Watts.

Environment

Operating temperature

0°– 40°C (22°– 104°F).

 

 

Storage temperature

-30°– 70°C (40°– 158°F).

 

 

Relative humidity

15% - 90% no condensing.

 

 

Operating altitude

Up to 3,000 m (10,000 ft.).

 

 

Operating ESD

4 kV.

 

 

1-2

Image 8
Contents Polycom RMX System Hardware Guide USA Regulatory Notices United States Federal Communication Commission FCCChinese Communication Certificate Singapore Certificate Table of Contents Table of Contents Main Features Hardware DescriptionRMX 2000 Specifications RMX 2000 System Capacities Following table summarizes the different system capacitiesSystem Functions MPM Mode MPM+ Mode MPMx Mode Resource Capacities MPM+Site Requirements Safety RequirementsRack Mount Safety Precautions Installation Precautions RMX 2000 Components RMX 2000 Front PanelComponent Description Cntl CPUComponent Description RMX 2000 Rear Panel RTM IPFollowing items appear on the RMX 2000 rear panel Management Network on page G-1RTM Isdn ISDN/PSTN Clock Source 3RMX 2000 RTM Isdn Rear Panel LayoutAll external connectors are located on the rear panel Cables Connected to the RTM IP & Isdn CardsRMX 2000 LEDs RMX 2000 Front Panel LEDsFollowing items appear on the RMX 2000 front panel ComponentCard removal Initiated The card Card Insertion Initiated If duringCntl Unit LED Color Description Name RMX 2000 Rear Panel LEDsFollowing LEDs appear on the RTM IP card ShMG LEDs Following LEDs appear on the RTM Isdn Function NameMPM/MPM+ and MPMx Configuration Modes MPM MPM+MPM+ Resource Capacities per Card Type MPMx Resource Capacities per Card Type MPMx, MPM+ and MPM ModesOperating Mode Selection During Startup / Restart System Information ChangesAll MPMx MPMx OnlyAn RMX has two MPM cards installed Both MPM cards are enabledInserted MPMx card is enabled Remove one MPM card Insert one MPMx cardRemaining MPM card is disabled An RMX has one MPMx card installedMPMx card is enabled Inserted MPM card is disabledRMX Chassis Types RMX 2000 General Information dialog box opensComponent Replacement Using the All Metal Ejector Lever Using the Modified PMC Compatible Ejector LeverFully Open The card is released from the MCU housing Types of Ejector Levers on RMX ComponentsReplacing the Cntl Module HandleHardware Description Replacing the Power Supply Module Replacing the Fan Drawer Replacing a Faulty MPM/MPM+/MPMx Card Removing the MPM/MPM+/MPMx Card from the MCUInstalling a New MPM/MPM+/MPMx Card in a Powered On RMX Installing the Replacement MPM/MPM+/MPMx CardReplacing a RTM Isdn Card PRI Cables Replacing the RTM IP Card