6Slide in the replacement RTM ISDN card.

7Insert the card into the slot until the ejector levers touch the front edge of the card cage.

8Push the ejector levers to their fully closed position.

9Tighten the captive screws on each side of the rear panel of the card, securing the RTM ISDN card to RMX.

10Turn ON the RMX 2000.

11Connect the RJ-45 terminated PRI cables into any of the slots labeled PRI1 - PRI12:

LAN

PRI Cables

Power

7 E1 or 9 T1 cables can be connected to each RTM ISDN card, up to a total of 14 E1 or 18 T1 PRI cables when two RTM ISDN cards are installed.

1-38

Image 44
Contents Polycom RMX System Hardware Guide USA Regulatory Notices United States Federal Communication Commission FCCChinese Communication Certificate Singapore Certificate Table of Contents Table of Contents Main Features Hardware DescriptionRMX 2000 Specifications RMX 2000 System Capacities Conferencing CapacitiesSystem Functions MPM Mode MPM+ Mode MPMx Mode Resource Capacities MPM+Site Requirements Safety RequirementsRack Mount Safety Precautions Installation Precautions RMX 2000 Components RMX 2000 Front PanelComponent Description Cntl CPUComponent Description RMX 2000 Rear Panel RTM IPFollowing items appear on the RMX 2000 rear panel RTM Isdn ISDN/PSTN Clock Source All external connectors are located on the rear panel Cables Connected to the RTM IP & Isdn CardsRMX 2000 LEDs RMX 2000 Front Panel LEDsComponent LED Color DescriptionCard removal Initiated The card Card Insertion Initiated If duringCntl Unit RMX 2000 Rear Panel LEDs LED Color Description NameShMG LEDs RTM Isdn Function NameMPMx MPM/MPM+ and MPMx Configuration ModesResource Type Maximum Possible Resources Per Card Card Resources Bandwidth Type HD720p HD1080p @30fps @60fps MPM+Up to 4MbpsMPMx Resource Capacities per Card Assembly Resource Type MPMx S MPMx DMPM+ MPMx Only AllMPMx MPMx Only MPM MPM+ Only MPM+ MPM+ Only MPMxMPM Only MPMCard Configuration Mode remains MPMx RMX Chassis Types RMX 2000 General Information dialog box opensComponent Replacement Using the All Metal Ejector Lever Types of Ejector Levers on RMX ComponentsReplacing the Cntl Module Hardware Description Replacing the Power Supply Module Replacing the Fan Drawer Replacing a Faulty MPM/MPM+/MPMx Card Removing the MPM/MPM+/MPMx Card from the MCUInstalling a New MPM/MPM+/MPMx Card in a Powered On RMX Installing the Replacement MPM/MPM+/MPMx CardReplacing a RTM Isdn Card PRI Cables Replacing the RTM IP Card