5Connecting the VS-88HN 8x8 HDMI Matrix Switcher

i

Always switch off the power to each device before connecting it to your VS-88HN. After connecting your VS-88HN, connect its power and then switch on the power to each device.

To connect the VS-88HN 8x8 HDMI Matrix Switcher as illustrated in the example in Figure 3:

1.Connect up to eight HDMI sources (for example, DVD players) to the IN

HDMI connectors.

You do not have to connect all the sources.

2.Connect the eight OUT HDMI connectors to up to eight HDMI acceptors (for

example, LCD displays with built-in speakers).

You do not have to connect all the outputs.

3.If required, connect a PC/controller to the RS-232 port (see Section 6.6) and/or the Ethernet port (see Section 6.7).

4.Connect the device to the mains electricity (not shown in Figure 3).

5.If necessary, acquire the EDID (see Section 6.2)

VS-88HN - Connecting the VS-88HN 8x8 HDMI Matrix Switcher

9

 

 

Image 12
Contents VS-88HN Page Figures Introduction Getting Started Achieving the Best PerformanceSafety Instructions Recycling Kramer Products Defining the VS-88HN 8x8 Hdmi Matrix Switcher OverviewVS-88HN Overview VS-88HN Overview Using the IR Transmitter Installing in a Rack Connecting the VS-88HN 8x8 Hdmi Matrix Switcher Connecting the VS-88HN 8x8 Hdmi Matrix Switcher Operating the VS-88HN 8x8 Hdmi Matrix Switcher Switching an Input to an OutputAcquiring the Edid Acquiring the Edid from One Output Selected input number flashes on the displayStoring and Recalling a Setting Acquiring the Default EdidResetting the IP Parameters To store a preset for example, to presetSwitching Between Protocol 2000 and Protocol Connecting via RS-232Connecting via Ethernet Connecting the Ethernet Port directly to a PC Local Area Connection Properties WindowInternet Protocol Version 4 Properties Window Internet Protocol Version 6 Properties Window Connecting the Ethernet Port via a Network Hub or Switch Control Configuration via the Ethernet PortUpgrading the Firmware Technical Specifications Default Communication Parameters RS-232Default Edid KMRVS-88HN Default Edid 0.0 Kramer Protocol Machine NumberInstruction Codes for Protocol VS-88HN Kramer Protocol Protocol Kramer Protocol 3000 SyntaxHost Message Format 11.1.2 Device Message FormatCommand Terms Device Long ResponseEntering Commands Command FormsChaining Commands Maximum String LengthKramer Protocol 3000 Commands Command Short Description Permission FormPage Safety Warning