Kramer Electronics VS-88HN user manual Device Long Response, Command Terms

Page 32

11.1.2.1Device Long Response

Echoing command:

Start

 

Address (optional)

 

Body

 

Delimiter

 

 

 

 

 

 

 

 

 

 

 

~

 

device_id@

 

Command SP [Param1 ,Param2 …]

result

 

 

CR LF

 

 

 

 

 

 

 

 

 

 

CR = Carriage return (ASCII 13 = 0x0D)

LF = Line feed (ASCII 10 = 0x0A)

SP = Space (ASCII 32 = 0x20)

11.1.3Command Terms

Command

A sequence of ASCII letters ('A'-'Z', 'a'-'z' and '-').

Command and parameters must be separated by at least one space.

Parameters

A sequence of alphanumeric ASCII characters ('0'-'9','A'-'Z','a'-'z' and some special characters for specific commands). Parameters are separated by commas.

Message string

Every command entered as part of a message string begins with a message starting character and ends with a message closing character.

Note: A string can contain more than one command. Commands are separated by a pipe ( '' ) character.

Message starting character '#' – For host command/query '~' – For device response

Device ID (Optional, for K-NET) K-NET Device ID followed by '@'

Query sign

'?' follows some commands to define a query request.

Message closing character

CR – For host messages; carriage return (ASCII 13)

CRLF – For device messages; carriage return (ASCII 13) + line-feed (ASCII 10)

VS-88HN - Protocol 3000

29

 

 

Image 32
Contents VS-88HN Page Figures Introduction Getting Started Achieving the Best PerformanceSafety Instructions Recycling Kramer Products Defining the VS-88HN 8x8 Hdmi Matrix Switcher OverviewVS-88HN Overview VS-88HN Overview Using the IR Transmitter Installing in a Rack Connecting the VS-88HN 8x8 Hdmi Matrix Switcher Connecting the VS-88HN 8x8 Hdmi Matrix Switcher Acquiring the Edid Operating the VS-88HN 8x8 Hdmi Matrix SwitcherSwitching an Input to an Output Acquiring the Edid from One Output Selected input number flashes on the displayStoring and Recalling a Setting Acquiring the Default EdidResetting the IP Parameters To store a preset for example, to presetConnecting via Ethernet Switching Between Protocol 2000 and ProtocolConnecting via RS-232 Connecting the Ethernet Port directly to a PC Local Area Connection Properties WindowInternet Protocol Version 4 Properties Window Internet Protocol Version 6 Properties Window Upgrading the Firmware Connecting the Ethernet Port via a Network Hub or SwitchControl Configuration via the Ethernet Port Technical Specifications Default Communication Parameters RS-232Default Edid KMRVS-88HN Default Edid 0.0 Kramer Protocol Machine NumberInstruction Codes for Protocol VS-88HN Kramer Protocol Protocol Kramer Protocol 3000 SyntaxHost Message Format 11.1.2 Device Message FormatCommand Terms Device Long ResponseEntering Commands Command FormsChaining Commands Maximum String LengthKramer Protocol 3000 Commands Command Short Description Permission FormPage Safety Warning