Delta Electronics LCP-200A4HSR manual Absolute Maximum Ratings, Recommended Operating Conditions

Page 2

Absolute Maximum Ratings

Parameter

Symbol

Min.

Storage Temperature

Ts

-40

Supply Voltage

VCC

0

Typ.

Max.

Unit

Note

85ºC

5 V

Recommended Operating Conditions

Parameter

Symbol

Min.

Case Operating Temperature

TC

-5

Supply Voltage

VCC

3.135

Note 1: See order information

Typ.

Max.

Unit

Note

70

ºC

1

3.465

V

 

Electrical Characteristics

(VCC=3.135V to 3.465V)

Parameter

Symbol

Min.

Total Supply Current

ICCT

 

Transmitter

 

 

Transmitter Differential Input Voltage

VDT

0.5

Transmitter Disable Input-High

VDISH

2

Transmitter Disable Input-Low

VDISL

0

Transmitter Fault Output-High

VTXFH

2

Transmitter Fault Output-Low

VTXFL

0

Receiver

 

 

Receiver Differential Output Voltage

VDR

0.35

LOS Output Voltage-High

VLOSH

2

LOS Output Voltage-Low

VLOSL

0

Output Data rise time/ fall time

tr/tf

 

Typ.

Max.

Unit

Note

300

mA

 

 

 

 

2.4

V

1

VCC+0.3

V

 

0.8V

VCC+0.3

V

2

0.8

V

2

 

 

 

2

V

3

VCC+0.3

V

1

0.8

V

1

1.5

ns

4

Notes

1.Internally AC coupled and terminated to 100 Ohm differential load.

2.Pull up to VCC with a 4.7K – 10KΩ resistor on host Board

3.Internally AC coupled, but requires a 100 Ohm differential termination at or internal to Serializer/ Deserializer.

4.These are 20%~80% values.

2

Aug., 2006

 

Rev. 0A

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 2
Contents Escon Sonet OC-3/SDH STM-1 DescriptionApplications Recommended Operating Conditions Electrical CharacteristicsAbsolute Maximum Ratings PA-PD Optical CharacteristicsRIN MOD-DEF2 Open Recommend Circuit Schematic Protocol IC SerDes ICPackage Outline Drawing for Metal Housing with Bail de-latch SFP timing parameters for SFP management TxdisableTxfault EMI Regulatory ComplianceOrdering information for SFP modules