Delta Electronics LCP-2488A4EDRxM Digital Diagnostic Monitoring Interface, Address Name

Page 11

LCP-2488A4EDRxM

8)Byte 84-91: Date code

9)Byte 95: Check sum of bytes 64-94

10)Byte 128 to 255 had been set hex 00

Digital Diagnostic Monitoring Interface

Alarm and Warning Thresholds (2-Wire Address A2h)

 

 

 

 

 

#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address

 

 

Name

 

 

Value (Dec.)

 

 

Unit

 

 

Note

 

 

 

 

 

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00-01

 

2

 

Temp High Alarm

 

TC (MAX.)+15

 

 

1

 

02-03

 

2

 

 

Temp Low Alarm

 

TC (MIN.)

 

 

 

 

 

 

 

04-05

 

2

 

Temp High Warning

 

TC (MAX.)+10

 

 

 

 

 

 

 

06-07

 

2

 

 

Temp Low Warning

 

TC (MIN.)+10

 

 

 

 

 

 

 

08-09

 

2

 

 

Voltage High Alarm

 

Vcc+5%

 

 

Volt

 

 

 

 

 

10-11

 

2

 

 

Voltage Low Alarm

 

Vcc-5%

 

 

 

 

 

 

 

 

12-13

 

 

2

 

 

Voltage High Warning

 

Vcc+3%

 

 

 

 

 

 

 

 

14-15

 

 

2

 

 

Voltage Low Warning

 

 

Vcc-3%

 

 

 

 

 

 

 

16-17

 

2

 

Bias High Alarm

 

IOP+10

 

 

mA

2

 

18-19

 

2

 

Bias Low Alarm

 

IOP-5

 

 

 

 

 

 

 

20-21

 

2

 

Bias High Warning

 

IOP+7

 

 

 

 

 

 

 

22-23

 

2

 

 

Bias Low Warning

 

IOP-3

 

 

 

 

 

 

 

24-25

 

2

 

 

TX Power High Alarm

 

P+3

 

 

dBm

 

 

3

 

 

26-27

 

2

 

 

TX Power Low Alarm

 

P-3

 

 

 

 

 

 

 

 

28-29

 

 

2

 

 

TX Power High Warning

 

P+2

 

 

 

 

 

 

 

 

30-31

 

 

2

 

 

TX Power Low Warning

 

 

P-2

 

 

 

 

 

 

 

32-33

 

2

 

RX Power High Alarm

 

P0+3

 

 

dBm

4

 

34-35

 

2

 

 

RX Power Low Alarm

 

PS-2

 

 

 

 

 

 

 

36-37

 

2

 

 

RX Power High Warning

 

P0+2

 

 

 

 

 

 

 

38-39

 

2

 

 

RX Power Low Warning

 

PS

 

 

 

 

 

 

 

40-45

 

16

 

 

Reversed

 

 

 

 

 

 

 

 

 

56-91

 

36

 

 

External Calibration Constants

 

 

 

 

 

 

 

 

 

92-94

 

3

 

 

Reversed

 

 

 

 

 

 

 

 

 

95

 

1

 

 

Checksum

 

 

 

 

 

 

 

5

 

96-97

 

2

 

Real Time Temperature

 

 

 

 

 

 

 

 

 

98-99

 

2

 

Real Time Supply Voltage

 

 

 

 

 

 

 

 

 

100-101

 

2

 

Real Time Tx Bias Current

 

 

 

 

 

 

 

 

 

102-103

 

2

 

 

Real Time Tx Optical Power

 

 

 

 

 

 

 

 

 

104-105

 

2

 

 

Real Time Rx Received Power

 

 

 

 

 

 

 

 

 

106-109

 

4

 

 

Reserved

 

 

 

 

 

 

 

 

 

110

 

1

 

 

Optional Status/ Control Bits

 

 

 

 

 

 

 

6

 

111

 

1

 

 

Reserved

 

 

 

 

 

 

 

 

 

112-119

 

8

 

 

Optional Set of Alarm and Warning

 

 

 

 

 

 

 

7

 

Notes:

1)TC: Case Operating temperature

2)IOP: Operating current at room temperature. The min. setting current is 0 mA.

3)P: Operating optical power of transmitter at room temperature.

4)P0: Overload optical power of receiver

11

Nov., 2006

 

Rev. 0A

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 11
Contents Description Duplex LC Connector interfaceRecommended Operating Conditions Electrical CharacteristicsAbsolute Maximum Ratings Mask of the eye diagram for the optical transmit signal Optical CharacteristicsLOS Open PLD / PAL Package Outline Drawing SFP timing parameters for SFP management Parameter Symbol Min Max UnitEnhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Unit Bytes Digital Diagnostic Monitoring InterfaceAddress Name State/ Control Bits Optional Set of Alarm and WarningOrdering information for SFP modules Regulatory Compliance