LCP-2488A4EDRxM 
SFP timing parameters for SFP management
| Parameter | Symbol | Min. | Max. | Unit | Note | 
| TX_DISABLE Assert time | t_off | 
 | 10 | μsec | 1 | 
| TX_DISABLE Negate time | t_on | 
 | 1 | msec | 2 | 
| Time to initialize, including | t_init | 
 | 300 | msec | 3 | 
| reset of TX_FAULT | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | |
| TX Fault Assert Time | t_fault | 
 | 100 | μsec | 4 | 
| TX_DISABLE to reset | t_rest | 10 | 
 | μsec | 5 | 
| LOS Assert Time | t_loss_on | 
 | 100 | μsec | 6 | 
| LOS Deassert Time | t_loss_off | 
 | 100 | μsec | 7 | 
| Serial ID Clock Rate | f_serial_clock | 
 | 100 | kHz | 
 | 
Notes:
1)Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal.
2)Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal.
3)From power on or negation of TX_Fault using TX Disable.
4)Time from fault to TX fault on.
5)Time TX Disable must be held high to reset TX_Fault
6)Time from LOS state to Rx LOS assert
7)Time from 
| 8 | Nov., 2006 | 
| 
 | Rev. 0A | 
| DELTA ELECTRONICS, INC. | www.deltaww.com |