Delta Electronics LCP-155B4JSRx Series manual Low 0, Delta Electronics, Inc

Page 5
Low (0 – 0.8V):

Notes:

1)TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.

2)TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 – 10 K Ω resistor. Its states are:

Low (0 – 0.8V):

Transmitter on

(>0.8, < 2.0V):

Undefined

High (2.0 – 3.465V):

Transmitter Disabled

Open:

Transmitter Disabled

3)Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩresistor on the host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID

4)LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.

5)VeeR and VeeT may be internally connected within the SFP module.

6)RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 370 and 2000 mV differential (185 – 1000 mV single ended) when properly terminated.

7)VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP connector pin. Maximum supply current is 300 mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1Ω should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30 mA greater than the steady state value. VccR and VccT may be internally connected within the SFP transceiver module.

8)TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100 Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 500 – 2400 mV (250 – 1200 mV single-ended), though it is recommended that values between 500 and 1200 mV differential (250 – 600 mV single-ended) be used for best EMI performance.

5

Nov., 2006

 

Rev. 0C

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 5
Contents z Compliant with Industry Standard RFT Electrical Connector and Cage z Compliant with SFP Transceiver MSA specificationz Single + 3.3V Power Supply and TTL Logic Interface z Duplex LC Connector interfaceAbsolute Maximum Ratings Electrical CharacteristicsRecommended Operating Conditions TransmitterMask of the eye diagram for the optical transmit signal Optical CharacteristicsPlug Seq. Pin engagement sequence during hot plugging SFP Transceiver Electrical Pad Layout Pin Function DefinitionsLow 0 PLD / PAL Protocol ICSerDes IC DELTA SFP ModulePackage Outline Drawing for Metal Housing with Bail de-latch SFP timing parameters for SFP management SymbolParameter UnitExample of initialization during hot plugging, TXDISABLE SFP timing parametersLCP-155B4JSR EEPROM Serial ID Memory Contents 2-Wire Address A0h Regulatory Compliance LCP-155B4JSRX1 X1 Temperature Ordering information for SFP modulesRelated Products