Delta Electronics LCP-155B4MSRx SFP timing parameters for SFP management, Txdisable, Txfault

Page 8

SFP timing parameters for SFP management

Parameter

Symbol

Min.

Max.

Unit

Unit Conditions

TX_DISABLE Assert

t_off

 

10

 

Time from rising edge of TX_DISABLE to

 

µsec

when the optical output falls below 10% of

time

 

 

 

 

 

nominal

 

 

 

 

 

TX_DISABLE

t_on

 

1

msec

Time from falling edge of TX_DISABLE to

 

when the modulated optical output rises

Negate time

 

 

 

 

 

above 90% of nominal

 

 

 

 

 

Time to initialize,

t_init

 

300

msec

From power on or negation of TX_Fault using

including reset of

 

TX_FAULT

 

 

 

 

TX Disable.

 

 

 

 

 

TX Fault Assert

t_fault

 

100

µsec

Time from fault to TX fault on.

Time

 

 

 

 

 

 

 

TX_DISABLE to

t_rest

10

 

µsec

Time TX Disable must be held high to reset

reset

 

TX_Fault

LOS Assert Time

t_loss_on

 

100

µsec

Time from LOS state to Rx LOS assert

LOS Deassert Time

t_loss_off

 

100

µsec

Time from non-LOS state to Rx LOS deassert

Serial ID Clock Rate

f_serial_clock

 

100

kHz

 

8

Jan. 2008

 

Rev. 0B

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 8
Contents Description ApplicationsPerformance Sonet OC-3/SDH STM-1Recommended Operating Conditions Electrical CharacteristicsAbsolute Maximum Ratings PA-PD Optical CharacteristicsMask of the eye diagram for the optical transmit signal MOD-DEF2 Open PLD / PAL Package Outline Drawing for Metal Housing with Bail de-latch SFP timing parameters for SFP management TxdisableTxfault SFP timing parameters Address Regulatory Compliance EMIOrdering information for SFP modules LCP-155B4MSRX1