Lennox International Inc 51M37 Default Thermostat Settings, Technical Specifications

Models: 51M37

1 54
Download 54 pages 14.47 Kb
Page 8
Image 8
Default Thermostat Settings

Default Thermostat Settings

Default thermostat settings are shown in table 2 and the default program is shown in table 3.

Table 2

Default Thermostat Settings

Mode

Heat (Permanent Hold

 

Mode)

 

 

Setpoint

70°F (or 21°C)

 

 

Fan

Auto

 

 

Filter Reminder

OFF

 

 

Maintenance Reminder

OFF

 

 

Equipment Protection

Reset Back to Zero

Timers

 

Table 3

Default Program Settings

 

 

Temperature

Temperature

Programs

Time

(Heat)

(Cool)

 

 

 

 

Weekday − A

6:00am

70_F / 21°C

78_F / 26°C

 

 

 

 

Weekday − B

8:00am

62_F / 17°C

85_F / 29°C

 

 

 

 

Weekday − C

6:00pm

70_F / 21°C

78_F / 26°C

 

 

 

 

Weekday − D

10:00pm

62_F / 17°C

82_F / 28°C

 

 

 

 

Weekend − A

6:00am

70_F / 21°C

78_F / 26°C

 

 

 

 

Weekend − B

8:00am

62_F / 17°C

85_F / 29°C

 

 

 

 

Weekend − C

6:00pm

70_F / 21°C

78_F / 26°C

 

 

 

 

Weekend − D

10:00pm

62_F / 17°C

82_F / 28°C

 

 

 

 

Weekday

Monday, Tuesday, Wednesday,

 

Thursday, Friday

 

 

 

 

Weekend

Saturday, Sunday

 

 

 

 

 

Technical Specifications

Thermostat Type

Electronic programmable thermostat for heat pump, 3-stage heat/2-stage cool.

NOTE − 2 stages of heat pump heat and one stage of auxil- iary (gas or electric) backup heat are supported.

Power Supply Range

18VAC − 30VAC (24VAC nominal), 60Hz

Table 2 CAUTION

24VAC is present on the terminals of the thermostat bracket. If removing the thermostat from the wall, use caution and avoid touching any of the connec- tor terminals on the wall bracket.

Also, when working with the thermostat dip switches, use a non−conductive tool and take cau- tion to avoid making any contact with the circuit board, its imprinted circuitry and its connector prongs.

Temperature Display

Display Scale: Fahrenheit or Celsius user selectable (via DIP switch; see figure 22)

Display range: 35°F (2°C) to 99°F (37°C)

Display resolution: 1°F (1°C)

Display Accuracy: +/−1°F

If the Fahrenheit/Celsius display must be changed, use a plastic, non−conductive tool to push the dip switch to the right position (see figure 22).

 

Changing Fahrenheit/Celsius Setting

1

 

2

 

3

 

4

 

5

 

6

PLUG IN (Use Care To Avoid Bending Prongs.)

 

F/C (Fahrenheit/Celsius) switch

 

shown in Celsius position

Figure 22

Temperature Measurement Range

Measurement Scale: Fahrenheit

Measurement Range: 35°F to 99°F

Measurement Resolution: 0.5°F

Measurement Accuracy: +/−1°F

Field Offset: via DIP switches to +/−3°F

Sampling Method: temperature measurements sampled every 15 seconds. Displayed temperature is the average of the last four measurements.

Temperature Setpoint Range

Setting range: 50°F (10°C) to 90°F (32°C)

Setting resolution: 1°F (1°C)